Exception: Hall call consoles beyond those required by Section 11B-411.2.1.1 shall be permitted to be provided outside the elevator landing and to be wall-mounted, pedestal-mounted, or mounted...
Search Results "Permit"
-
11B-411.2.1.1 Location
-
Section 36.210 Smoking (Section-By-Section Analysis and Response to Comments)
The reference to smoking in section 501 merely clarifies that the Act does not require public accommodations to accommodate smokers by permitting them to smoke in places of public accommodations...
-
§ 38.95(b)(3) Emergency operation
otherwise, shall be capable of being operated in a manner that could be hazardous to the lift occupant or to the operator when operated according to manufacturer's instructions, and shall not permit...
-
§ 38.125(b)(3) Emergency operation
otherwise, shall be capable of being operated in a manner that could be hazardous to the lift occupant or to the operator when operated according to manufacturer's instructions, and shall not permit...
-
11B-201.3 Temporary and permanent structures
Structures and equipment directly associated with the actual processes of construction are not required to be accessible as permitted in Section 11B-203.2. ◼...
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-1005.1 Accessible routes
Exceptions: Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in Section 11B-1003.2.1....
-
11B-411.2.1.1 Location
Exception: Hall call consoles beyond those required by Section 11B-411.2.1.1 shall be permitted to be provided outside the elevator landing and to be wall-mounted, pedestal-mounted, or mounted...
-
11B-608.7 Thresholds
Exception: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (12.7 mm) high threshold would...
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
304.3.2 T-Shaped Space
The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm....
-
403.5.1 Clear Width
EXCEPTION: The clear width shall be permitted to be reduced to 32 inches (815 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated by...
-
201.3 Temporary and Permanent Structures
Structures and equipment directly associated with the actual processes of construction are not required to be accessible as permitted in 203.2. ...
-
602.2 Clear Floor Space
EXCEPTION: A parallel approach complying with 305 shall be permitted at units for children’s use where the spout is 30 inches (760 mm) maximum above the finish floor or ground and is 3½...
-
608.7 Thresholds
EXCEPTION: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would...
-
1005.1 Accessible Routes
Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in 1003.2.1. 2....
-
608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the...
-
1005.1 Accessible Routes
Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in 1003.2.1. 2....
-
902.1 General
EXCEPTION: Dining surfaces and work surfaces for children's use shall be permitted to comply with 902.4. Advisory 902.1 General....
-
211.3 More Than Minimum Number
EXCEPTION: Where 50 percent of the drinking fountains yields a fraction, 50 percent shall be permitted to be rounded up or down provided that the total number of drinking fountains complying...
-
502.3.3 Marking
Because these requirements permit the van access aisle to be as wide as a parking space, it is important that the aisle be clearly marked....
-
803 Dressing, Fitting, and Locker Rooms
However, permitted overlaps are limited. For example, an object with knee and toe clearance can overlap only one arm or the base of T-shaped turning space (304.3.2)....
-
Section 36.311 Mobility Devices (Section-by-Section Analysis)
In both the NPRM and the final rule, § 36.311(a) states the general rule that in any areas open to pedestrians, public accommodations shall permit individuals with mobility disabilities...
-
XII. Examinations and Courses
., permit additional time)....