Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance. 2....
Search Results "Permit"
-
407.2.2.2 Visible Signals
-
Perpendicular and Angled Parking Spaces (R309.3) (Section-by-Section Analysis)
Two accessible parking spaces are permitted to share a common access aisle....
-
410.6 Doors and Gates
EXCEPTION: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
R409.6 Gripping Surface
Pedestrians with disabilities and others benefit from continuous gripping surfaces that permit users to reach the fingers outward or downward to grasp the handrail....
-
15. Laundry rooms
(Where front loading washers are not provided, management will be expected to provide assistive devices on request if necessary to permit a resident to use a top loading washer.)...
-
Complaints
Passengers who are deaf or hard of hearing must be permitted to communicate with a CRO via a TTY on request....
-
1007.7.2 Outdoor facilities
Where exit access from the area serving outdoor facilities is essentially open to the outside, an exterior area of assisted rescue is permitted as an alternative to an area of refuge....
-
Openings in Beach Access Routes
Openings up to a half of an inch (13 millimeters) wide are permitted....
-
Openings in Outdoor Recreation Access Route Surfaces
Openings up to a half of an inch (13 millimeters) wide are permitted....
-
vi. Rehabilitation Equipment
For example, individuals with hearing impairments or blindness or low vision might require equipment or furniture to permit their full participation in cardiopulmonary rehabilitative services...
-
609.3 Spacing
EXCEPTION: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1 1/2 inches (38 mm) minimum....
-
505.10 Handrail Extensions
In assembly areas, extensions shall not be required for ramp handrails in aisles serving seating where the handrails are discontinuous to provide access to seating and to permit crossovers...
-
1015.3 Viewing Space
EXCEPTION: Guards or similar safety barriers shall be permitted to obstruct the viewing space to the extent the obstruction is necessary for the guard or safety barrier to serve its intended...
-
M303.2.4.2 Knee Clearance
Between 9 inches (230 mm) and 27 inches (685 mm) above the floor, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for every 6 inches (150 mm) in height...
-
M302.4.1 Clearance in Base
Equipment components are permitted to be located within 8 inches (205 mm) maximum of the centerline of the clearance width....
-
M301.4.1 Clearance in Base
Equipment components are permitted to be located within 8 inches (205 mm) maximum of the centerline of the clearance width....
-
Private Sector Facilities (Places of Public Accommodation & Commercial Facilities)
transit facility or airport terminal In mixed use facilities that otherwise qualify for this exception, vertical access is required to any story containing occupancies not permitted...
-
§ 35.151(c)(1)
Departures from particular requirements of either standard by the use of other methods shall be permitted when it is clearly evident that equivalent access to the facility or part of the...
-
§ 35.151(c)(2)
Departures from particular requirements of either standard by the use of other methods shall be permitted when it is clearly evident that equivalent access to the facility or part of the...
-
§ 38.97(a)
(a) Where provided, handrails or stanchions within the passenger compartment shall be placed to permit sufficient turning and maneuvering space for wheelchairs and other mobility aids to...
-
§ 38.115(a)
(a) Where provided, handrails or stanchions within the passenger compartment shall be placed to permit sufficient turning and maneuvering space for wheelchairs and other mobility aids to...
-
§ 37.201(a)
(a) Whenever an OTRB makes an intermediate or rest stop, a passenger with a disability, including an individual using a wheelchair, shall be permitted to leave and return to the bus on the...
-
1.1.5 Referenced codes
The National Fire Codes, standards, and the Fire Protection Handbook of the National Fire Protection Association are permitted to be used as authoritative guides in determining recognized...
-
11B-303.3 Beveled
A change in level of ½ inch (13 mm) is permitted to be ¼ inch (6.4 mm) vertical plus ¼ inch (6.4 mm) beveled....