Section 306.3.3 covers the current ADA Standards for the minimum required depth for knee clearance.
Search Results "Clear"
Commonly Searched Documents
-
Minimum Required Depth: ADA Standard Section 306.3.3
-
Approach: ADA Standard Section 802.1.4
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
11B-809.2.2 Turning space
For example, in kitchens, Section 11B-804.3.1 requires at least one work surface with clear floor space complying with Section 11B-306 to be centered beneath....
- LaCantina Contemporary Clad Door System
- Activar Hiawatha 535/509/536/537 Solid 1 inch Diameter Pulls
-
Break Out Opening: ADA Standard Section 404.3.6
Section 404.3.6 covers the current ADA Standards for the break out openings at swinging or sliding doors and gates.
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
T505.3 Location of Operable Parts
Operable parts shall be located so that they are reachable by passengers using wheelchair when parked in a clear space 30 inches (760 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
R407.4 Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 915 mm (3.0 ft) minimum....
-
1134A.5, Item 1
There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to provide for the maneuvering...
-
1134A.5, Item 1
There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to provide for the maneuvering...
-
Utilities at Recreation Sites
size, or location), the clear floor or ground space only has to comply with requirements to the extent practicable....
-
4.34.5.2(1)
(1) Clear floor space at the water closet shall be as shown in Fig. 47(a). The water closet may be located with the clear area at either the right or left side of the toilet....
- Magnuson Group 2000 Series Magazine Racks
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
- Inpro Corporation SignScape® Digital Graphic Signs
-
12101(b)(1)
(1) to provide a clear and comprehensive national mandate for the elimination of discrimination against individuals with disabilities; Sec. 12101 note: Findings and Purposes of ADA...
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
Amenities
Therefore, they must provide 32 clear inches. 612 Saunas and Steam Rooms. 612.2 Bench....
-
1009.5.1 Transfer Platform
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. ...
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....