Doors, doorways, and gates that are part of an accessible route shall comply with 404. EXCEPTION: Doors, doorways, and gates designed to be operated only by security personnel...
Search Results "Latch Side Clearance"
-
404.1 General
-
404.1 General
404.1 General. Doors, doorways, and gates that are part of an accessible route shall comply with 404. EXCEPTION: Doors, doorways, and gates designed to be operated only by...
-
608.2 Size and Clearances for Shower Compartments
608.2 Size and Clearances for Shower Compartments. Shower compartments shall have sizes and clearances complying with 608.2....
-
Comparison of Single-User Toilet Room “Pairs” With Fixtures Side-by-Side: Plan 1A and Plan 1B
Comparison of Single-User Toilet Room “Pairs” With Fixtures Side-by-Side: Plan 1A and Plan 1B 1991 Standards Plan-1A Pair: 1991 Standards with Out-Swinging...
-
1003.3.1 Boat Slip Clearance
1003.3.1 Boat Slip Clearance. Boat slips shall provide clear pier space 60 inches (1525 mm) wide minimum and at least as long as the boat slips....
-
11B-606.6 Adjacent side wall or partition
11B-606.6 Adjacent side wall or partition....
-
Vertical clearance and protruding objects
• Entrances and aisles with adequate head clearance and minimal projections into the path of travel result in easier navigation for people with lessened visual acuity or those who may be...
-
306 Knee and Toe Clearance
Section 306 defines the minimum clearances for knees and toes beneath fixed objects. Few comments addressing this section were received....
- Corbin Russwin Inc. FE5400S Mult-Point Exit Device Latching System
-
1003.3.2 Boarding Pier Clearances
1003.3.2 Boarding Pier Clearances....
-
Issue 10: Braille (right side up?)
Issue 10: Braille (right side up?) Where the APS device includes the street name in Braille, care must be taken to install the signs in the correct location and orientation. ...
-
FIGURE 11A-10A KITCHEN SPECIFICATIONS
(1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel...
-
1133A.1 General
Kitchens shall be on an accessible route and shall comply with this section. (See Figure 11A-10A.) (1) 30" minimum countertop space for sink installation with...
-
1133A.1 General
Kitchens shall be on an accessible route and shall comply with this section. (See Figure 11A-10A.)
- Don-Jo Mfg., Inc. 5" Hospital Latch 4550
- PEMKO 5 5/16" Latching Panic Saddle Threshold No. 273x224-FGT
-
Exterior Routes
Walks, sidewalks and ramps. 11B-403.3 11B-405 Vertical clearances/protrusions along circulation paths. 11B-307...
-
Exterior Routes
Walks, sidewalks and ramps. 11B-403.3 11B-405 Vertical clearances/protrusions along circulation paths. 11B-307...
-
1003.3.1 Boat Slip Clearance
Advisory 1003.3.1 Boat Slip Clearance Exception 3....
- Access Board: Multi User Toilet Room Layout
-
5.1 Transfer Surface Height
5.1 Transfer Surface Height
-
5.1.4 Transfer Surface Height Measurement
5.1.4 Transfer Surface Height Measurement. The transfer surface height should be measured from the floor to the highest point on the seat in an uncompressed state, inclusive of...
-
11B-504.8 Floor identification
They must be tactile, and located at the latch side of the door inside the stairway as prescribed by CBC Section 11B-703.4....