The 1991 Standards do not allow an in-swinging door in a toilet or bathing room to overlap the required clear floor space at any accessible fixture....
Search Results "Clear Width"
-
Alterations and water closet clearances in single-user toilet rooms with in-swinging doors. (Section-by-Section Analysis)
-
Ramps M303:3.3, 3.3.1, 3.3.2
The clear width of ramp runs would be required to be 36 inches minimum....
-
Benches [1011.2]
A minimum of 36 by 48 inches of clear ground space must be provided near a bench, with one side of the clear space adjoining an ORAR or trail as applicable....
-
Additional benefits of water closet clearance standards
clearance provisions will have nonmonetized benefits that promote equal access and equal opportunity for individuals with disabilities, and will further the ADA’ s purpose of providing ‘‘a clear...
-
Additional benefits of water closet clearance standards
clearance provisions will have non-monetized benefits that promote equal access and equal opportunity for individuals with disabilities, and will further the ADA's purpose of providing ‘‘a clear...
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
The features that make this possible are: an accessible route to and through the room; an entry door with adequate clear width, maneuvering clearance, and accessible hardware;...
-
Technical Memorandum TM 2013-17 Water Closet Clearance - Overlap
TM 2013-17 Water Closet Clearances - Overlap Effective Date: June 1, 2013 2012 TAS Reference: 604.3.2 Based on TAS 106.3 and the application of terms and definitions...
-
L. Lavatory
L. Is there at least one lavatory (wash basin) in each public restroom that has each of the following characteristics... ...a 29" high clearance under the front edge and the top...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear...
-
11B-604.3.1 Size
11B-604.3.1 Size. Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured...
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
Yes, as long as the necessary clear floor space shown in Figure 7(a) is provided....
-
1017.8.2 Width
Where resting intervals are provided adjacent to the trail tread, the resting interval clear width shall be 36 inches (915 mm) minimum....
-
1017.8.2 Width
Where resting intervals are provided adjacent to the trail tread, the resting interval clear width shall be 36 inches (915 mm) minimum....
-
2.5.3 Width
Where resting intervals are provided adjacent to an outdoor recreation access route, the resting interval clear width shall be 36 inches (915 mm) minimum. ...
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
4.32.2 Seating
If seating spaces for people in wheelchairs are provided at fixed tables or counters, clear floor space complying with 4.2.4 shall be provided....
-
4.32.2 SEATING
If seating spaces for people in wheelchairs are provided at tables, counters, or work surfaces, clear floor space complying with 4.2.4 shall be provided....
-
§100.205(c)
(c) All covered multifamily dwellings for first occupancy after March 13, 1991 with a building entrance on an accessible route shall be designed and constructed in such a manner that—
-
Outdoor Constructed Features
The proposed rule based the size of the clear ground space at outdoor constructed features on the dimensions for clear floor or ground surfaces in 305.2 of the Architectural Barriers Act...
-
4.3.11.3* Stairway Width
Each stairway adjacent to an area of rescue assistance shall have a minimum clear width of 48 inches between handrails....