EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
Search Results "Side Transfer Surface"
Commonly Searched Documents
-
1017.7.2 Cross Slope
-
1017.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
- AccessRec Mr. Boardwalk Modular Walkway
-
Avoid the extremes of surface reflectivity and contrast (slides 11 and 13)
We don’t have to have highly reflective surfaces that will still reflect light but spread it, diffuse that light instead of pinpoint reflections....
-
2.5.4 Slope
Where the surface is paved or is elevated above the natural ground, the slope shall not be steeper than 1:48 (2 percent) in any direction. ...
-
Section F: Voting Area
_______________________ Location name:______________________ F Within the Voting Area Yes No N/A Comments/Remedies F1 Are floor surfaces...
- Access Board: Obstructed Side Reach
-
Cross Slope (R302.6) (Section-by-Section Analysis)
In exterior environments, a maximum cross slope of 2 percent is generally accepted as adequate to allow water to drain off paved walking surfaces....
- Pilot Rock RT Series End Accessible Recycled Plastic Picnic Table
-
2. What does the ADA require for accessibility of pools?
One means of entry/exit must be a fixed pool lift or sloped entry; the other entry can be a transfer wall, transfer system, or pool stairs....
-
4.25.3 Height
Clothes rods or shelves shall be a maximum of 54 in (1370 mm) above the finish floor for a side approach....
- Figure 505.6 Horizontal Projections Below Gripping Surface – Drawing from the U.S. Access Board
- Smith System Lift Desk Work Surface with Crank
-
4.1.2(17)
(17) If fixed or built-in seating, tables, or work surfaces are provided in accessible spaces, at least 5 percent, but always at least one, of seating spaces, tables, or work surfaces shall...
- Husky 10" Multi-Function Standard Digital Level
-
11B-405.3 Cross slope
Cross slope is the slope of the surface perpendicular to the direction of travel. Cross slope is measured the same way as slope is measured (i.e., the rise over the run)....
-
11B-405.3 Cross slope
Cross slope is the slope of the surface perpendicular to the direction of travel. Cross slope is measured the same way as slope is measured (i.e., the rise over the run)....
-
11B-405.3 Cross slope
Cross slope is the slope of the surface perpendicular to the direction of travel....
-
1008.4.2 Clear Floor or Ground Space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
1008.4.2 Clear Floor or Ground Space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
7.2.2.1 Determining Impracticability
The surface is not firm and stable for a distance of 45 feet or more (14 m). Limiting Factor 3. ...
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
Shower Compartments
• The 1991 Standards and the 2010 Standards permit a ½-inch maximum curb in transfer-type showers....
-
4.16.2 Clear Floor Space
However, in accommodating assisted transfers, these guidelines were less of an issue than providing space adjacent to the water closet for caregivers and including a 5’ turning radius in...