Shower stalls that are 36 in by 36 in (915 mm by 915 mm) wide provide additional safety to people who have difficulty maintaining balance because all grab bars and walls are within...
Search Results "Side Transfer Surface"
Commonly Searched Documents
-
A4.21.1 GENERAL
-
4.21.2 Size and Clearances
4.21.2 Size and Clearances. Minimum guidelines for roll-in shower stalls are based on residential size fixtures (30" x 60" minimum or the space used by a standard residential...
- Willoughby Industries US-HC Cabinet Shower
-
M301.3 Supports (Section-by-Section Analysis)
This is an introductory section. An editorial change was made to this section as a result of the change in M301.3.2, described below, to replace the word “stirrups” with the term...
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
308.3.2 Obstructed High Reach
The high side reach shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches (255 mm) maximum....
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
11B-308.3.2 Obstructed high reach
The high side reach shall be 48 inches (1219 mm) maximum for a reach depth of 10 inches (254 mm) maximum....
- Inpro Corporation JointMaster® DR Series Seal Expansion Joint Systems
-
T503.3 Steps at Front Doorways
The walking surface on steps serving the front doorway of non-rail vehicles shall be lighted with 2 foot-candles (22 lux) minimum of illumination when the vehicle doors are open....
- Choosing Level Size
-
4.26.4 Eliminating Hazards
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
4.26.4 ELIMINATING HAZARDS
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
11B-308.3.2 Obstructed high reach
The high side reach shall be 48 inches (1219 mm) maximum for a reach depth of 10 inches (254 mm) maximum....
- NanoPave® JSS 2-in-1 Joint Stabilizer and Sealer
-
1017.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1017.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1017.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
-
Avoid the extremes of surface reflectivity and contrast (slides 11 and 13)
We don’t have to have highly reflective surfaces that will still reflect light but spread it, diffuse that light instead of pinpoint reflections....
-
2.5.4 Slope
Where the surface is paved or is elevated above the natural ground, the slope shall not be steeper than 1:48 (2 percent) in any direction. ...
-
Section F: Voting Area
_______________________ Location name:______________________ F Within the Voting Area Yes No N/A Comments/Remedies F1 Are floor surfaces...
- Access Board: Obstructed Side Reach
-
Cross Slope (R302.6) (Section-by-Section Analysis)