Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4....
Search Results "Recreational Surfacing"
-
11B-809.9.3 Removable base cabinets
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
-
M302.2.3 Size
Transfer surfaces shall be 21 inches (610 mm) wide minimum and 17 inches (430 mm) deep minimum....
-
Step 3: Apply the Accessibility Provisions
This step involves looking at FSTAG, sections 7.4.1 through 7.4.8, which contain the technical requirements for trail grade, cross slope, resting interval, surface, clear tread width, passing...
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers....
- Beneficial Designs High Efficiency Trail Assessment Process (HETAP) Software 3.0 Wheeled Instrumentation Sensor Package for Data Collection
-
5.1.4 Transfer Surface Height Measurement for M301 and M302
5.1.4 Transfer Surface Height Measurement for M301 and M302 The Committee recommends capturing the transfer surface height at the highest point of the seat in an uncompressed state, inclusive...
-
ETA Questions: Interpretation of the "Changes in Level Are Not Permitted" Requirements
There are a number of places in the 2010 ADA Standards where the phrase "Changes in level are not permitted" occurs. However, the interpretation of this phrase is not clearly...
-
6.8.2 Grade and cross slope
Where the surface is paved or is elevated above the natural ground, the surface shall not be steeper than 1:48 (2 percent) in any direction....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
- USDA Forest Service Built Environment Image Guide (BEIG)
-
M302.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision added to the final rule in conjunction with the new requirement of a low height range in M302.2.1....
-
M302.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used by patients in the seated position of 21 inches wide and 15 inches deep (proposed M302.2.2)....
- Mobi-Mat® Recpath™ ADA Beach Access Mat
-
Problem Three
Problem Three: Accessible parking spaces or access aisles are on a sloped surface and do not provide a level area for a safe transition from the voter’s car to a wheelchair....
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
This section requires fire building surfaces to be 9 inches minimum above the ground, and cooking surfaces to be 15 inches minimum and 34 inches maximum above the ground....
-
Cross Slope
Comment. Comments indicated that specifications for cross slope (1:48 maximum) are not referenced in the curb ramp section. Response. In the final rule, the Board has clarified...
-
1011.4.1 Height
The tops of picnic tables shall comply with 902.3.
-
Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Imaging Equipment
Accessibility Standards for Medical Diagnostic Equipment Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations - Imaging Equipment Final...
-
Handrails
...are there handrails on both sides of the stair at a uniform height of 34"-38" above the front edge of the step? [ADA Stds. 4.9] Yes __ No __ N/A __ Comments:...
-
A5. Accessible Parking Spaces
A5. Are all accessible parking spaces, including the access aisle, relatively level (1:50 or 2%) in all directions? [ADA Stds 4.6.3] If No: Look for a nearby area that is relatively...
-
1011.4.1 Height
The tops of picnic tables shall comply with 902.3.
-
1.2.3 Landings
1.2.3 Landings. Both measurements of ramp landings as described in Section 1.1.15 should not exceed a plus tolerance of 0.5%.