The transfer surface shall be 21 inches (610 mm) wide minimum and 15 inches (381 mm) deep minimum. Advisory M302.2.2 Size....
Search Results "Ground Surface"
Commonly Searched Documents
-
M302.2.2 Size
-
1016.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
-
5.1 Q...Would the first story of single-story dwelling units over the parking level be required to be accessible?
The Guidelines adopt and amplify the definition of ground floor found in HUD's regulation implementing the Fair Housing Act (see 24 CFR 100.201) to indicate that . . .where the first floor...
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
4.7.8 Utility and Dump Station Hookup Clear Floor or Ground Space
The clear floor or ground space around utility and dump station hookups shall be at least 30 inches (760 mm) by 60 inches (1525 mm)....
- Kompan, Inc. Hammock ELE400006
-
§ 38.57(c)
(c) The diameter or width of the gripping surface of handrails and stanchions shall be 11/4 inches to 11/2 inches or provide an equivalent gripping surface and shall provide a minimum 11...
-
1.2 Q. Does the Fair Housing Act cover four one-story dwelling units that share common walls and have individual entrances?
The Fair Housing Act applies to all units in buildings consisting of four or more dwelling units if such buildings have one or more elevators; and ground floor dwelling units in other buildings...
-
5.2 Q. If a building design contains a mix of single-story flats on grade and single-story flats located above grade over a public parking area, do the flats over the parking area have to be accessible?
The definition of ground floor in the Guidelines states, in part, that ground floor means a floor of a building with a building entrance on an accessible route....
-
Reach Ranges (Advisory)
inches for 9 to 12 year-olds Side Reach Forward Reach The reach ranges appropriate for use by children who use wheelchairs to access play components are intended for ground-level...
-
5.1.3 Transfer Surface Low Height Options for M301 and M302
5.1.3 Transfer Surface Low Height Options for M301 and M302 The Committee did not agree on a final low height recommendation....
-
1018.10 Dune Crossings
The curbs or barriers shall prevent the passage of a 2 inch (50 mm) diameter sphere, where any portion of the sphere is within 2 inches (50 mm) of the crossing surface....
-
1018.10 Dune Crossings
The curbs or barriers shall prevent the passage of a 2 inch (50 mm) diameter sphere, where any portion of the sphere is within 2 inches (50 mm) of the crossing surface....
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2....
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2....
-
2.1 Q. If a building includes three residential dwelling units and one or more commercial spaces, is the building a covered multifamily dwelling under the Fair Housing Act?
Covered multifamily dwellings are buildings consisting of four or more dwelling units, if such buildings have one or more elevators; and ground floor dwelling units in other buildings consisting...
-
1008.4 Play Components
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4....
-
1008.4 Play Components
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4....
-
4.5.2.1 Forward Approach
The clear floor or ground space for a forward approach shall be 36 inches (915 mm) by 48 inches (1220 mm)....
-
4.5.2.2 Side Approach
The clear floor or ground space for a side approach shall be 30 inches (760 mm) by 60 inches (1525 mm)....
-
Medical Diagnostic Equipment Accessibility Standards Sub Committee Recommendations Stretcher Final Report
Equipment Features Addressed in Technical Criteria Types Of Equipment To Which Technical Criteria Applies Supine, prone, or side-lying position (M301) Transfer surface...
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....