The MDE NPRM proposed to require transfer supports to be capable of resisting vertical and horizontal forces of 250 pounds at all points (proposed M305.2.2)....
Search Results "Head Support"
-
a. Structural Strength
-
Supports (M301.3, M302.3, and M305.2)
M301.3, M302.3, and M305.2 provide technical criteria for transfer and positioning supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic...
-
5.9.1 Standing Supports In Reference To Mammography Equipment
5.9.1 Standing Supports In Reference To Mammography Equipment. The requirement for standing supports should be removed for mammography equipment....
-
M304.2.2 Standing Supports
Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3....
-
603.2 Information on Accessibility and Compatibility Features
ICT support services shall include information on the accessibility and compatibility features required by 602.2....
-
4. Overhead Objects
4 Is the voting area free of overhead objects that voters may pass under with the bottom edge lower than 80 inches above the floor? Yes _____ No _____
-
C2-3 Objects Hanging Over Pedestrian Routes
C2-3. Are all objects that hang over the pedestrian routes 80 inches or more above the route? If No, can the objects be removed or relocated, or can a detectable object be added...
-
603.2 Information on Accessibility and Compatibility Features
ICT support services shall include information on the accessibility and compatibility features required by 602.2....
-
1. Standing Supports
The second commenter, a manufacturer, expressed concerns that the proposed rule was treating supports on breast platforms as standing supports, explaining that this was not the supports’...
-
Shower Spray Unit and Water: ADA Standard Section 607.6
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
-
11B-607.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
11B-607.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
§ 1194.41(a)
(a) Product support documentation provided to end-users shall be made available in alternate formats upon request, at no additional charge....
-
5.9.1 Standing Supports Recommendation In Reference To Mammography Equipment
5.9.1 Standing Supports Recommendation In Reference To Mammography Equipment The Committee recommends removing the requirement for standing supports on mammography equipment....
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3....
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3....
-
Figure M1: Overview of M301 Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position
[See subsections ...]
-
Protruding Objects
One element of a barrier-free meeting space for participants who are blind or have low vision requires cane-detectable protruding objects and sufficient head clearance....
-
603.2 Information on Accessibility and Compatibility Features (Section-by-Section Analysis)
Accessibility and Compatibility Features (Section-by-Section Analysis) This proposed section complements the product documentation requirements in section 602 by proposing that ICT support...
-
C206.1 General
Where support documentation and services are provided for ICT, telecommunications equipment manufacturers shall provide such documentation and services in conformance with Chapter 6, upon...
-
C206.1 General
Where support documentation and services are provided for telecommunications equipment and customer premises equipment, manufacturers shall ensure that such documentation and services conform...
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
transfer supports on tables with transfer depths of less than or equal to 24 inches and positioning supports for transfer depths greater than 24 inches....
-
E2-c
Are any interior stairs along these routes configured with a cane-detectable warning or a barrier that prevents travel into the area with less than an 80-inch high head clearance so that...
-
11B-608.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....