Section 610.3.2 covers the current ADA Standards for L-shaped shower compartment seats.
Search Results "Fixed Shower Head"
Commonly Searched Documents
-
L-Shaped Seats: ADA Standard Section 610.3.2
-
§ 37.101(c) Fixed Route System. Vehicle Capacity of 16 or Fewer
(c) Fixed Route System. Vehicle Capacity of 16 or Fewer....
-
11B-608.3.3 Alternate roll-in type shower compartments
11B-608.3.3 Alternate roll-in type shower compartments....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Guest Rooms with Mobility Features: ADA Standard Section 224.2
Section 224.2 covers scoping requirements in the current ADA Standards for transient lodging guest rooms with mobility features.
-
1b
Do they have a fixed or folding seat between 17"-19" above the floor, onto which a person who uses a wheelchair may transfer to shower?...
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. ...
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Q. Other Showers in Accessible Guestrooms/Suites
Other Showers in Accessible Guestrooms/Suites - Accessible guestrooms/suites that are not required to have roll-in showers may have an accessible bathtub, a small shower as shown in Figure...
-
608.3.1 Transfer Type Shower Compartments
608.3.1 Transfer Type Shower Compartments....
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches long minimum shall be installed on the head end wall at the front edge of the bathtub....
-
11B-610.1 General
Seats in bathtubs and shower compartments shall comply with Section 11B-610....
-
4.23.8 Bathing and Shower Facilities
If tubs or showers are provided, then at least one accessible tub that complies with 4.20 or at least one accessible shower that complies with 4.21 shall be provided.....
-
4.23.8 BATHING AND SHOWER FACILITIES
If tubs or showers are provided, then at least one accessible tub that complies with 4.20 or at least one accessible shower that complies with 4.21 shall be provided....
-
610 Seats
[See subsections ...]
-
610 Seats
[See subsections ...]
-
610 Seats
610 Seats
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
608.3.1 Transfer Type Shower Compartments
Figure 608.3.1 Grab Bars for Transfer Type Showers...
-
CHAPTER 9: BUILT-IN ELEMENTS
[See subsections ...]
-
DIVISION 9: BUILT-IN ELEMENTS
[See subsections ...]
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
4.3.2 Seat Height
4.3.2 Seat Height Seat height is an important dimension for establishing the height of built-in seating, toilet heights, tub heights, shower seat heights and other transfer related surfaces...