ADAAG does not specify the minimum number of steps that comprise a set of "stairs." Most building codes require handrails for a certain change in level or number of steps. (In new...
Search Results "Exit Stairway"
Commonly Searched Documents
-
Steps
-
4.9.1 MINIMUM NUMBER
Stairs required to be accessible by 4.1 shall comply with 4.9.
-
III-7.5110 Stairs
III−7.5110 Stairs (ADAAG §4.1.3(4)). Interior and exterior stairs must comply if they go between levels not connected by an elevator, ramp, or lift.
-
4.9 STAIRS
[See subsections ...]
-
11B-504.1 General
Stairs shall comply with Section 11B-504.
-
11B-504.1 General
Stairs shall comply with Section 11B-504.
-
1011.4 Raised character and Braille exit signs
1011.4 Raised character and Braille exit signs. Tactile exit signs shall be required at the following locations:...
-
1013.4 Raised character and Braille exit signs
1013.4 Raised character and Braille exit signs. Tactile exit signs shall be required at the following locations:...
-
1011.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1011.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
-
1013.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1013.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps. 3....
-
[F] 907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps....
-
Stairways [§504]
Stairways [§504] Requirements for stairways address treads and risers, surfaces, nosings, and handrails....
-
Raised character and Braille exit signs
Raised character and Braille exit signs shall comply with Chapter 11A, Section 1143A or Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5....
-
[F] 907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, exterior exit stairs and exterior exit ramps. 3. ...
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
1007.7.6 Stairway
1007.7.6 Stairway. Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
Egress Signage
Section 216.4 provides specific requirements for means of egress, including exit doors, areas of refuge, and directional signs....
-
11B-207.1 General
Doors that provide access only to interior or exterior stairways shall not be required to comply with Section 11B-404....
-
1011.4, Item 5
Each exit door through a horizontal exit that is required to comply with Section 1011.1 shall be identified by a sign with the words, “TO EXIT.”...
-
1013.4, Item 5
Each exit door through a horizontal exit that is required to comply with Section 1013.1 shall be identified by a sign with the words, “TO EXIT.” ...
-
11B-206.2.3.1 Stairs and escalators in existing buildings
In alterations and additions, where an escalator or stair is provided where none existed previously and major structural modifications are necessary for the installation, an...
-
1011.4, Item 4
Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1011.1, shall be identified by a tactile exit sign with the words “EXIT...