Stairs shall comply with Section 11B-504.
Search Results "Enclosed Exit Stairway"
Commonly Searched Documents
-
11B-504.1 General
-
Scoping [4.1.3(4)]
Specifications in 4.9 benefit people who have difficulty walking or using stairs. Compliance is required where stairs are the only connection between two levels, such as between...
-
A4.9 Stairs
[See subsections ...]
-
4.9 Stairs
[See subsections ...]
-
A4.9.1 Minimum Number
Only interior and exterior stairs connecting levels that are not connected by an elevator, ramp, or other accessible means of vertical access have to comply with 4.9.
-
4.9.1* Minimum Number
Stairs required to be accessible by 4.1 shall comply with 4.9.
-
Stairs [4.9]
[See subsections ...]
-
Steps
ADAAG does not specify the minimum number of steps that comprise a set of "stairs." Most building codes require handrails for a certain change in level or number of steps. (In new...
-
4.9.1 MINIMUM NUMBER
Stairs required to be accessible by 4.1 shall comply with 4.9.
-
III-7.5110 Stairs
III−7.5110 Stairs (ADAAG §4.1.3(4)). Interior and exterior stairs must comply if they go between levels not connected by an elevator, ramp, or lift.
-
4.9 STAIRS
[See subsections ...]
-
11B-504.1 General
Stairs shall comply with Section 11B-504.
-
11B-504.1 General
Stairs shall comply with Section 11B-504.
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
Raised character and Braille exit signs
Raised character and Braille exit signs shall comply with Chapter 11A, Section 1143A or Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5....
-
Stairways [§504]
Stairways [§504] Requirements for stairways address treads and risers, surfaces, nosings, and handrails....
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
Egress Signage
Section 216.4 provides specific requirements for means of egress, including exit doors, areas of refuge, and directional signs....
-
1007.7.6 Stairway
1007.7.6 Stairway. Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
1011.4, Item 5
Each exit door through a horizontal exit that is required to comply with Section 1011.1 shall be identified by a sign with the words, “TO EXIT.”...
-
1013.4, Item 5
Each exit door through a horizontal exit that is required to comply with Section 1013.1 shall be identified by a sign with the words, “TO EXIT.” ...
-
1011.4, Item 4
Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1011.1, shall be identified by a tactile exit sign with the words “EXIT...
-
1013.4, Item 4
Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1013.1, shall be identified by a tactile exit sign with the words “EXIT...
-
11B-206.2.3.1 Stairs and escalators in existing buildings
In alterations and additions, where an escalator or stair is provided where none existed previously and major structural modifications are necessary for the installation, an...