Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2.
Search Results "Elevator Building"
-
11B-408.3.2 Swinging doors
-
11B-408.3.1 Sliding doors
Sliding hoistway and car doors shall comply with Sections 11B-407.3.1 through 11B-407.3.3 and 11B-408.4.1.
-
Audible Hall Signals
Comments from the elevator industry indicated that hall signals currently fall within this range. Response....
-
3. Discussion of Comments on Related Fair Housing Issues Compliance Deadline
to make changes to buildings near completion....
-
Alterations [4.1.6(1)(f) & (k)]
Thus, the exception from the requirement for an elevator in buildings with less than 3 stories or with less than 3,000 square feet per floor applies to altered facilities as well, including...
-
§ 36.401(d) Elevator exemption.
(d) Elevator exemption....
-
Alterations and Additions
Alterations and Additions When a building or facility is renovated or altered or added to for any purpose, the alterations or additions must comply with the ADA Standards....
-
Sec.36.401(a) General
(a) General.
-
Section 35.151(d) Scope of Coverage (Section-by-Section Analysis)
The Department is proposing § 35.151(d) to clarify that the requirements established by this section, including those contained in the proposed standards, prescribe what is necessary...
-
§ 36.401(a) General
(a) General.
- International Code Council (ICC)
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated...
-
11B-1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3.
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section...
-
Sec.36.404(a)(2)
(2) For the purposes of this section, shopping center or shopping mall means --
-
§ 36.404(a)(2)
(2) For the purposes of this section, shopping center or shopping mall means –
-
407.2.1.6 Keypads
Where keypads are provided, keypads shall be in a standard telephone keypad arrangement and shall comply with 407.4.7.2.
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface.