Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
Search Results "Elevator Building"
-
11B-1008.3.2.1 Size
-
11B-411.4.10 Support rail
Support rails complying with Section 11B-407.4.10 shall be provided on at least one wall of the car.
-
11B-411.4.9 Emergency communication
Emergency communication shall comply with Section 11B-407.4.9.
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated...
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7.
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3.
-
11B-411.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-411.4.8.2.
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section...
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
III-9.0000 CERTIFICATION
Regulatory references: 28 CFR 36.601-36.608.
-
TEST NO. 1 – INDIVIDUAL BUILDING TEST
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
TEST NO. 1 – INDIVIDUAL BUILDING TEST
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: The slopes of the undisturbed site...
-
Historic Preservation [4.1.7]
Alterations to such facilities are required to be done in full compliance with the alteration requirements for other types of buildings....
-
Car Controls [4.10.12]
lights beside buttons are permitted but cannot interfere with the placement of raised and Braille characters) emergency controls are not required by ADAAG but are addressed by the elevator...
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5.
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5.
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5.
-
408.4.4 Leveling
Elevator car leveling shall comply with 407.4.4....
-
408.4.4 Leveling
Elevator car leveling shall comply with 407.4.4....
-
408.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
408.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
11B-408.4.4 Leveling
Elevator car leveling shall comply with Section 11B-407.4.4....
-
408.4.4 Leveling
Elevator car leveling shall comply with 407.4.4....