Floor designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
Search Results "Elevator Building"
-
11B-411.2.3.1 Floor designation signs
-
11B-411.2.3.1 Floor designation signs
Floor designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
CHAPTER 3: BUILDING BLOCKS
Chapter 3 discusses the building blocks that the ADA Standards are built on.
-
Transfer Supports
Consideration must be given to the distance between the transfer system and the elevated play components it is intended to facilitate....
- Kompan, Inc. Elements Play Structures Tower ELE400050
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
11B-411.4.8.1.2 Location
Location of indicators shall comply with Section 11B-407.4.8.1.2.
-
11B-411.4.8.1.1 Size
Characters shall comply with Section 11B-407.4.8.1.1.
-
Hall Call Buttons [4.10.3]
These specifications apply to all hall call buttons provided, including those that serve cars that operate independently from others in the same bank or lobby. Recommendation:...
-
11B-411.4.8.1.1 Size
Characters shall comply with Section 11B-407.4.8.1.1.
-
11B-411.4.8.1.2 Location
Location of indicators shall comply with Section 11B-407.4.8.1.2.
-
11B-411.4.8.1.2 Location
Location of indicators shall comply with Section 11B-407.4.8.1.2.
-
11B-411.4.8.1.1 Size
Characters shall comply with Section 11B-407.4.8.1.1.
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
User activation of door close (or automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s...
-
III-5.4200 Professional office of a health care provider
The ADA's elevator exemption does not apply to buildings housing the offices of a health care provider....
-
Transfer Steps
Maneuvering space and clear space is not required on elevated structures or at elevated play components reached by a transfer system. ...
-
Sec.36.601 Definitions
Code means a State law or local building code or similar ordinance, or part thereof, that establishes accessibility requirements....
-
11B-206.2.17.1 Ground level and elevated play components
The accessible route shall connect ground level play components required to comply with Section 11B-240.2.1 and elevated play components required to comply with Section 11B-240.2.2, including...
-
11B-206.2.17.1 Ground level and elevated play components
The accessible route shall connect ground level play components required to comply with Section 11B-240.2.1 and elevated play components required to comply with Section 11B-240.2.2, including...
-
11B-206.2.17.1 Ground level and elevated play components
The accessible route shall connect ground level play components required to comply with Section 11B-240.2.1 and elevated play components required to comply with Section 11B-240.2.2, including...
-
207.1 General
Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition...
-
1003.2.13.5 Areas of refuge
Every required area of refuge shall have direct access to an enclosed stairway complying with Sections 1003.2.13.2 and 1005.3.2 or an elevator complying with Section 1003.2.13.3....
-
11B-407.4.7.1.2 Location
Raised characters or symbols and Braille designations shall be placed immediately to the left of the control button to which the designations apply. [2010 ADAS] EXCEPTION: Where...
-
407.4.8.1.1 Size
Characters shall be ½ inch (13 mm) high minimum.