For example, you could say, “I will need help transferring on and off the exam table.” If you will need it, ask if they have transfer or lifting equipment and/or a lift team....
Search Results "Transfer Wall"
-
4. Getting What You Need During Your Visit
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
610.3.1 Rectangular Seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall....
-
Controls [4.21.5]
Controls [4.21.5] Controls and shower units can be located on any wall but where a folding seat is provided they must be located to be within reach of a person on the seat....
-
11B-604.7.2 Disposal units
Sanitary napkin disposal units, if provided, shall comply with Section 11B-309.4 and shall be wall mounted and located on the sidewall between the rear wall of the toilet and the toilet...
-
§ 38.107(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
§ 38.123(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
§382.81(a)
(a) For a passenger who uses an aisle chair to access the aircraft and who cannot readily transfer over a fixed aisle armrest, you must provide a seat in a row with a movable aisle armrest...
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
ASME
This document does not permit the use of inclined stairway chairlifts which do not provide platforms because such lifts require the user to transfer to a seat....
-
Adjustable height/gap protocol
There are seven columns; the left one lists the height of the transfer in inches, the rest of the columns list the percentages of subjects that could attain the transfer at increasing gap...
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
704.11.1 Parapet construction
Parapets shall have the same fire-resistance rating as that required for the supporting wall, and on any side adjacent to a roof surface, shall have noncombustible faces for the uppermost...
-
610.3.1 Rectangular Seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall....
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-604.7.2 Disposal units
Sanitary napkin disposal units, if provided, shall comply with Section 11B-309.4 and shall be wall mounted and located on the sidewall between the rear wall of the toilet and the toilet...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
Living Room
Arms well forward on chairs Biodegradable grass cloth Wall texture offers traction when leaning on the wall to prevent slip and fall....
-
Clear Floor or Ground Space: ADA Standard Section 804.3.1
conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish floor extends under the cabinetry; and (c) the walls...
-
Pool Lifts: ADA Standard Section 1009.2
Pool lift seats that consist of materials that resist corrosion and provide a firm base to transfer will be usable by a wider range of people with disabilities....
-
Willoughby Industries ETW-1490-FM-HC Floor Mount Wall Outlet Rear Mounted ADA Blow Out Type Flush Toilet
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Accessible Route to Play Components
The remaining play components are permitted to be connected by a transfer system....
-
7(2)(b)(iv)