Also included is a mechanical height rod allowing users to measure weight and height together. ...
Search Results "Character Height (Raised)"
Commonly Searched Documents
- 1100KL HR Digital Platform Scale Extra Wide Handrail with Mechanical Height Rod
- Spectrum Industries Inc. Freedom One Sit-to-Stand Lectern™ Adjustable Height Lecterns
-
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS In the absence of Committee consensus commending a departure from the existing broadly accepted transfer surface...
- Caroma® USA Sydney Low Profile 270 Easy Height Round Front Plus Toilet
-
11B-703.7 Symbols of accessibility
Symbols of accessibility, such as the International Symbol of Accessibility (ISA), which are included on signs with raised characters and Braille are not required to be raised....
- TOTO® MS854114EL Commercial Eco UltraMax One-Piece Toilet ADA Height
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm), with bars...
-
11B-810.4 Bus signs
Bus route identification signs shall comply with Sections 11B-703.5.1 _|Finish and Contrast|_ through 11B-703.5.4 _|Character Proportions|_, and Sections 11B-703.5.7 _|Stroke Thickness|_...
-
11B-810.4 Bus signs
Bus route identification signs shall comply with Sections 11B-703.5.1 _|Finish and Contrast|_ through 11B-703.5.4 _|Character Proportions|_, and Sections 11B-703.5.7 _|Stroke Thickness|_...
-
Tactile Signage
Tactile Signage Raised and Braille characters are required on signs that "designate permanent rooms and spaces."...
- American Standard Cadet 1.6 gpf Right Height Elongated Pressure Assisted Toilet
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
T702.5 Stroke Thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
When toilet and bathing facilities have doorway openings instead of doors, such as at airports or stadiums, the geometric identification symbol should be located at the proper height adjacent...
- Pressalit Care PLUS Support Arm Height and Sideways Adjustable Swing Grab Bar
-
703.6.1 Pictogram Field
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
-
703.6.1 Pictogram Field
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
-
Features of Accessible Parking Spaces
Notes: 1. Parking space identification sign with the international symbol of accessibility complying with 703.7.2.1 mounted 60 inches minimum above the ground surface measured...
- Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar with Leg
-
R410.8 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....