The surface of beach access routes and resting intervals must be firm and stable. Sand is not a firm and stable surface. Additional information on firm and stable surfaces is...
Search Results "Grab Bar Clearance"
-
Surface [1018.3]
-
Location [F248.3]
Beach access routes must coincide with or be located in the same general area as pedestrian access points that serve the beach.
-
Surface and Clear Tread Width on Beach Access Routes
A beach access route must have a firm, stable surface, and have a clear tread width of 60 inches (1,525 millimeters) minimum.
-
Slopes and Resting Intervals for Beach Access Routes
Running slope, also referred to as "grade," is the lengthwise slope of a beach access route, parallel to the direction of travel. Sections of beach access route of any length are...
-
6.6 Clear Width
The clear width of beach access routes shall be 60 inches (1525 mm) minimum. Exception: At dune crossings, the clear width of beach access routes that are not removable shall...
-
F248.3 Location
This section requires beach access routes to coincide with or be located in the same general area as pedestrian access points to the beach.
-
1018.4 Clear Width
The clear width of beach access routes shall be 60 inches (1525 mm) minimum. EXCEPTION: At dune crossings, the clear width of beach access routes that are not removable shall be...
-
5.7.1 Lift Compatibility Clearance in Base for M301
The proposed clearance in the base provision allows the legs of a portable floor lift to fit under the base of the equipment....
-
§ 38.95(b)(13) Handrails
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....
-
1134A.5, Item 1
1. Floor space. There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower...
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel...
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel approach to...
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel approach to...
-
B. Slopes
B. Slopes - Examine each of the interior routes described above: ...excluding accessible ramps, do the corridors have running slopes (i.e.: in the direction of travel) not more...
-
J1
J1. If the drinking fountain is a wall-mounted unit, is there clear floor space at least 30 inches wide (36 inches if it is in an alcove) x 48 inches long in front of the drinking...
-
807.2.3 Beds
807.2.3 Beds. Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide,...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide,...
-
1134A.5, Item 1
1. Floor space. There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to...
-
§ 38.159(d)(2) Location and size
(2) Location and size. The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches (760 mm) by 48 inches...
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel...
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel...
-
Size and Clearances [4.21.2]
Size and Clearances [4.21.2] Clear floor space is specified for side transfers. Where a forward approach is provided, space at least 60 inches wide provides room for turning....
-
M301.4 Lift Compatibility (Section-by-Section Analysis)
in base (proposed M301.4.1) or clearance around base (proposed M301.4.2) technical requirements....