., there is no need to install an elevator, and platform accessibility can be achieved by use of a relatively inexpensive mini-high platform)....
Search Results "Platform Edge"
-
Section 37.59 Differences in Accessibility Completion Date Requirements
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
105.2.2 ASME
ASME A18.1-2003 Safety Standard for Platform Lifts and Stairway Chairlifts (see 410.1). Advisory 105.2.2 ASME....
-
105.2.2 ASME
ASME A18.1-2003 Safety Standard for Platform Lifts and Stairway Chairlifts, (see 410.1). Advisory 105.2.2 ASME....
- BraunAbility Vista 2 Wheelchair Lift for School Buses, Cutaway Buses, and Paratransit Vans
-
1134A.8, Item 8
Where mirrors or towel fixtures are provided they shall be mounted with the bottom edge no higher than 40 inches (1016 mm) from the floor....
-
Surface
To prevent injuries, the wall surface must have rounded edges and not be sharp....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
609.5 Surface Hazards
Grab bars and any wall or other surfaces adjacent to grab bars shall be free of sharp or abrasive elements and shall have rounded edges....
-
1134A.8, Item 8
Where mirrors or towel fixtures are provided they shall be mounted with the bottom edge no higher than 40 inches (1016 mm) from the floor....
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub....
-
Overview of Proposed Guidelines
including requirements for curb ramps or blended transitions, and detectable warning surfaces; Pedestrian street crossings at roundabouts, including requirements for detectable edge...
-
M305.2.5 Surface Hazards (Section-by-Section Analysis)
Sharp edges or abrasive elements may injure and cause the patient to lose their grip during positioning or transfer.”...
-
607.4.2.2 Control End Wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub. [ECTCR UFAS 4.34.5.4(3), Fig. 48(a)]...
-
607.4.2.3 Head End Wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. [ECTCR UFAS 4.34.5.4(3), Fig. 48(a)] ...
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
H25
Is the clear width of the door at least 32 inches (measured between the face of the door and the edge of the opening) when the door is open 90 degrees?...
-
11B-609.5 Surface hazards
Grab bars and any wall or other surfaces adjacent to grab bars shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers....
-
406.6 Diagonal Curb Ramps
Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow....