Yes, it is a protruding object hazard based solely on section 307, but so is the (code compliant) lavatory with its (required) 29" high front edge, and the 8" deep (code compliant) shelf...
Search Results "Platform Edge"
-
Re: Section 307 Protruding Objects
-
Exposed Pipes and Surfaces [4.19.4]
Exposed sharp or abrasive edges are prohibited....
-
General [5.1]/ Access Aisles [5.3]
The required clear width (36 inches minimum) is specified for the clearance between the edges of fixed tables or between table edges and walls....
-
§ 38.159(b)(4) Power or equipment failure
Platforms stowed in a vertical position, and deployed platforms when occupied, shall have provisions to prevent their deploying, falling, or folding any faster than 12 inches/second (305...
-
1117B.1, Item 5
The bubbler outlet orifice shall be located within 6 inches (152mm) of the front edge of the drinking fountain and within 36 inches (914 mm) of the floor....
-
1117B.1, Item 4
The bubbler outlet orifice shall be located within 6 inches (152mm) of the front edge of the drinking fountain and within 36 inches (914 mm) of the floor....
-
QUESTION: WHAT DOES THE RULE MEAN BY “EXISTING FREIGHT OPERATIONS?”
, and therefore, level-entry boarding is always required at such a platform....
-
502.2 Documented Accessibility Features (Section-by-Section Analysis)
Specifically, under proposed 502.2, platform features that are defined in the platform documentation as accessibility features would be required to conform to requirements in accompanying...
-
302.2 Carpet
Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303....
-
302.2 Carpet
Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303....
-
302.2 Carpet
Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303....
-
11B-504.5 Nosings
The radius of curvature at the leading edge of the tread shall be ½ inch (12.7 mm) maximum....
-
11B-504.5 Nosings
The radius of curvature at the leading edge of the tread shall be ½ inch (12.7 mm) maximum....
-
11B-504.5 Nosings
The radius of curvature at the leading edge of the tread shall be ½ inch (12.7 mm) maximum....
-
Adjustable height/gap protocol
Adjustable height/gap protocol: From the initial setup, a gap separating the device and platform was introduced with the plywood blocks of 3.5” (8.9cm) and then the height of platform was...
-
§ 38.109 Between-car barriers
Where vehicles operate in a high-platform, level-boarding mode, and where between-car bellows are not provided, devices or systems shall be provided to prevent, deter or warn individuals...
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
4.15.4 Controls
Unit controls shall be front mounted or side mounted near the front edge....
-
4.15.4 CONTROLS
Unit controls shall be front mounted or side mounted near the front edge....
-
1003.2.12.1 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
-
T503.5 Exterior Illumination for Boarding and Alighting Areas
Where doorways have steps, the illumination shall be 1 foot-candle (11 lux) minimum for a distance of 3 feet (915 mm) measured beyond the outside edge of the doorway or bottom step tread...
-
1003.2.12.1 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
-
1015.3 Height
On stairways and stepped aisles, from the line connecting the leading edges of the tread nosings. On ramps and ramped aisles, from the ramp surface at the guard....
-
§ 38.81(c)
(c) The doorways of vehicles not operating at lighted station platforms shall have outside lights which provide at least 1 foot-candle of illumination on the station platform or street surface...