A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
Search Results "Door Clear Width"
-
11B-1009.4.1 Clear deck space
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
1010.1.9.1 Hardware
Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11A or 11B shall not require tight grasping, tight pinching or twisting of the...
-
Plan 4B: 13-Foot Wide Accessible Guest Room
Features include an alternate roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to adjacent guest room. Furnishings include two beds. ...
-
Entrance
One commenter requested clarification on whether "entrance" refers to an entry door to a dwelling unit, or an entry door to the building. Response....
-
Maneuvering Clearances [§404.2.4]
Maneuvering Clearances [§404.2.4] Required maneuvering clearances provide space for opening and proceeding through doors, doorways, and gates using wheelchairs and other mobility aids...
-
Recessed Lavatories
Recessed Lavatories Recessing lavatories can provide space for side transfers while allowing a narrower room width....
-
Q4.) Are conditions like door closers that require force in excess of the maximum allowed by the standards considered true tolerances or are they simply non-compliance with the maintenance requirements of 35.133 or 36.211?
A4.) In our opinion, the plain language of the term “Construction and Manufacturing Tolerances” does not include adjustable conditions that can meet the detailed requirements when...
-
1004.1 Clear Floor Space
1004.1 Clear Floor Space. Exercise machines and equipment shall have a clear floor space complying with 305 positioned for transfer or for use by an individual seated in a wheelchair....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
3. Desk clear floor space
Desk clear floor space: If provided, desks and writing tables need to have a 30-inch by 48-inch clear floor space that extends 19 inches under the desk and any fixed seat needs to be removable...
-
Requirement 3. Usable doors.
Section 100.205(c)(2) provides that covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that all the doors designed to allow...
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
611.2 Clear Floor Space
611.2 Clear Floor Space. A clear floor or ground space complying with 305 positioned for parallel approach shall be provided....
-
Plan 5A: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, clothes closet with swinging door, and door connecting to adjacent guest room....
-
§ 38.25 Doors, steps and thresholds
[See subsections ...]
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location. ...
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location....
-
Disinformation Corridor Exhibit
The force required to push or pull open the red door leading out of the exhibit is 15 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
Rising Sun Exhibit
The force required to push or pull open the painted door leading out of the exhibit is 14 lbf, which exceeds the maximum allowable door opening force of 5 lbf....