Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
Search Results "Door Clear Width"
-
11B-408.3.2.2 Duration
-
3. Desk clear floor space
Desk clear floor space: If provided, desks and writing tables need to have a 30-inch by 48-inch clear floor space that extends 19 inches under the desk and any fixed seat needs to be removable...
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
611.2 Clear Floor Space
611.2 Clear Floor Space. A clear floor or ground space complying with 305 positioned for parallel approach shall be provided....
-
Are doors or gates to employee work areas required to comply?
Entry doors or gates to employee work areas are required to meet applicable requirements, including those for maneuvering clearance, on the exterior, but not the interior....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
11B-604.8.1.1.2 Maneuvering space with side-opening door....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location. ...
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location....
-
203.9 Employee Work Areas
Spaces and elements within employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3 and shall be designed and constructed so that individuals with...
-
203.9 Employee Work Areas
203.9 Employee Work Areas. Spaces and elements within employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3 and shall be designed and constructed so...
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Door Arm Pivot Variations Video
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Adjusting Spring Door Tension Video
-
1009.2.3 Clear Deck Space
1009.2.3 Clear Deck Space. On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
- Access Board: Automatic Door Controls
-
11B-604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....
-
604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum....