Aisles must be at least 5 feet wide, although a wider aisle (8 feet wide minimum) is helpful at zones that serve transit vehicles with lifts or ramps....
Search Results "Switchback Ramp"
Commonly Searched Documents
-
Passenger Loading Zones [4.6.6]
-
11B-206.7.5 Existing site constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. [2010 ADAS] Advisory 206.7.5 Existing Site Constraints. ...
-
11B-206.2.3.2 Distance to Elevators
new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp...
-
11B-206.7.5 Existing site constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory 11B-206.7.5 Existing site constraints....
-
11B-206.2.3.2 Distance to Elevators
new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp...
-
i) Grievance Procedures
City's grievance procedure.22 At trial, Kirola testified to having made a single request for the removal of an access barrier; namely, her July 2006 request that the City install curb ramps...
-
Boating facilities. (Section-by-Section Analysis)
Sections 206.2.10, 235.2, and 235.3 of the 2004 ADAAG require a specified number of boat slips and boarding piers at boat launch ramps to be accessible and connected to an accessible route...
-
Boating facilities. (Section-by-Section Analysis)
Sections 206.2.10, 235.2 and 235.3 of the 2004 ADAAG require a specified number of boat slips and boarding piers at boat launch ramps to be accessible and connected to an accessible route...
-
R306.3.1 Separation
European and Australian roundabouts provide a 610 mm (24 inch) width of tactile surface treatment from the centerline of the curb ramp or blended transition across the full width of the...
-
III-4.4300 Standards to apply
Are portable ramps permitted? Yes, but only when the installation of a permanent ramp is not readily achievable....
-
Where Platform Lifts are Permitted [§206.7]
recreational boating facilities, and fishing piers and platforms They also are permitted in new construction where topography or other existing exterior site constraints make a ramp...
-
1013.4 Raised character and braille exit signs
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
B. Accessible Routes To All Service/Activity Areas
Yes ___ No ___ Number of Steps: _______ If No, is there a ramp, lift, or elevator? Yes ___ No ___ Type of device: _______ B1-b....
-
240.2.1 Ground Level Play Components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
11B-240.2.1 Ground level play components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
Feature 2 - Routes to the Building Entrance
Where ramps are used, they cannot be steeper than 1:12 (8.33% incline). Ramps with a vertical rise of more than 6 inches must have handrails on both sides....
-
F240.2.1 Ground Level Play Components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
240.2.1 Ground Level Play Components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
Two Step Transfer Evaluation
The two-step transfers consisted of an adjacent transfer (no gap between two steps) and a ramped transfer over a constant 8 inch gap between two steps....
-
11B-240.2.1 Ground level play components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
11B-240.2.1 Ground level play components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
1011.4, Item 2
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
T402.8.1 Deployment to Roadways or to Curb Height Boarding and Alighting Areas
The running slope of ramps and bridgeplates used for deployment to the roadway or to curb-height boarding and alighting areas shall be 1:6 maximum, as measured to ground level with the non-rail...
-
1013.4, Item 2
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...