Cross slope requirements are contained in R304.5.3 for curb ramps and blended transitions, and in R407.3 for ramps....
Search Results "Switchback Ramp"
Commonly Searched Documents
-
R302.6 Cross Slope
-
Slope [4.3.7]
Where the running slope of an accessible route exceeds 5% it must be treated as a ramp or curb ramp. A maximum cross slope of 2% is recognized for drainage....
-
11B-405.9.2 Curb or barrier
To prevent wheel entrapment, the curb or barrier shall provide a continuous and uninterrupted barrier along the length of the ramp....
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps. 3....
-
[F] 907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps....
-
11B-405.9.2 Curb or barrier
To prevent wheel entrapment, the curb or barrier shall provide a continuous and uninterrupted barrier along the length of the ramp....
- Walk-A-Sured Roll-On Anti-Slip Safety Coating System
- Walk-A-Sured Clear Anti-Slip Safety Coating System
-
4. Grievance Procedure
Curb ramp requests submitted through the City's grievance procedure trigger an investigation by DPW....
- Inclusion Solutions BigBell™ Alert System
-
Suggestion by Eldon Tipping
Eldon Tipping As published in Concrete Construction magazine, September 1998, Eldon Tipping made suggestions for a specification for sloped random - traffic floors such as parking decks, ramps...
-
B8. Accessible Route
Does an accessible route connect the curb ramp to the accessible entrance? [ADA Stds 4.1.2(1)]...
-
11B-303.3 Beveled
Changes in level exceeding ½ inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps). FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL...
-
T503.5 Exterior Illumination for Boarding and Alighting Areas
Where doorways have ramps, bridgeplates or lifts, the illumination shall be 1 foot-candle (11 lux) minimum for a distance of 3 feet (915 mm) measured beyond the edge of the ramp, bridgeplate...
-
303.3 Beveled
Changes in level exceeding ½ inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps). Figure 303.3 Beveled Change in Level...
- Harmar CPL400P Portable Vertical Platform Lift
-
Detectable Warnings
This warning was required since the sloped surfaces of curb ramps remove a tactile cue provided by curb faces....
-
f-ii
Is the change in level from the floor to the lift surface ramped or beveled? [ADA Standards §§ 4.11.2, 4.5.2] Yes No...
-
Section B: Passenger Drop-Off Area
(§503.5) B4 Is a curb ramp provided if a curb separates the access aisle from the accessible route to the accessible entrance?...
-
Chapter 4: Accessible Routes
Chapter 4 contains technical requirements for accessible routes (402) and the various components of such routes, including walking surfaces (403), doors, doorways and gates (404), ramps...
-
11B-405.9.2 Curb or barrier
To prevent wheel entrapment, the curb or barrier shall provide a continuous and uninterrupted barrier along the length of the ramp....
-
303.3 Beveled
Changes in level exceeding 1/2 inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps)....
-
Components (R302.2) (Section-by-Section Analysis)
Curb ramps and blended transitions must comply with the technical requirements in R302.7 and R304. Ramps must comply with the technical requirements in R407....
-
Scoping [4.1.3(4)]
Stairs do not have to comply where vertical access (ramp, elevator, or lift) is provided....