Exit devices are a critical part of a door opening or access system and will provide safe and reliable service when properly applied and maintained. Von Duprin Division designs and...
Search Results "Swing Grab Bar"
- Allegion Von Duprin 88 Series Cross Bar Exit Device
- Allegion Von Duprin 55 Series Cross Bar Exit Devices
-
Flush Controls on Toilets
If administrative authorities require flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then that bar may be split or shifted...
-
[F] WORKSTATION
Examples include ticket booths; the employee side of grocery store check stands; the bartender area behind a bar; the employee side of snack bars, sales counters and public counters; guardhouses...
-
1132A.8 Hand-activated door hardware
Latching and locking doors that are hand-activated and on an accessible route shall be operable with a single effort by lever-type hardware, panic bars, push-pull activating bars or other...
-
[F] WORKSTATION
Examples include ticket booths; the employee side of grocery store check stands; the bartender area behind a bar; the employee side of snack bars, sales counters and public counters; guardhouses...
-
[F] WORKSTATION
Examples include ticket booths; the employee side of grocery store check stands; the bartender area behind a bar; the employee side of snack bars, sales counters and public counters; guardhouses...
-
1132A.8 Hand-activated door hardware
Latching and locking doors that are hand-activated and on an accessible route shall be operable with a single effort by lever-type hardware, panic bars, push-pull activating bars or other...
-
604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
-
11B-224.1.2 Guest room doors and doorways
Bathrooms doors shall be either sliding or hung to swing in the direction of egress from the bathroom. [2010 ADA Standards] 224.1.2 Guest Room Doors and Doorways....
-
604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
D2
Other possible solutions are to enlarge the door opening, use a swing clear hinge, or, if a double-leaf door, replace with uneven width doors....
-
M9
. 48-inch minimum by 66-inch minimum clear floor space for toilet 2. 48-inch minimum by 30-inch minimum clear floor space for lavatory 3. 60-inch minimum turning space 4. door swing...
-
11B-604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
Controls
Clear floor space at controls should be located outside the door swing....
- Figure 404.2.4.1(k) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side with Closer – Drawing from the U.S. Access Board
- Figure 404.2.4.1(i) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Pull Side with Closer – Drawing from the U.S. Access Board
-
E. Restaurants and Concessions:
PSE shall continue to provide accessible tables, marked with the International Symbol for Accessibility, within the bar areas of the Red Bull Bar and Captain Morgan's Bar located in the...