Dining surfaces include, but are not limited to, bars, tables, lunch counters, and booths....
Search Results "Swing Grab Bar"
Commonly Searched Documents
-
902.1 General
- Bobrick ClassicSeries Recessed Paper Towel Dispenser B-359
-
Table of Contents
Drinking Fountains 603 Toilet and Bathing Rooms 604 Water Closets and Toilet Compartments 605 Urinals 606 Lavatories and Sinks 607 Bathtubs 608 Shower Compartments 609 Grab...
-
241 and 612 Saunas and Steam Rooms
Doors are not permitted to swing into the clear floor or ground space for the accessible bench....
-
703.4.2 Location
characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing...
-
404.2.3 Clear Width
Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees....
-
703.4.2 Location
characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing...
-
404.2.3 Doorways - Clear Width
Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees....
-
4.4 Equipment Barriers and Solutions
Use an assistive device, such as a transfer board, to make moving from your wheelchair to the equipment easier Purchase equipment with removable or swing-away seats to allow a wheelchair...
-
404.2.3 Doorways - Clear Width
Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees....
-
11B-404.2.3 Clear width
Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees....
-
11B-404.2.3 Clear width
Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees....
-
Definitions of residential facilities and transient lodging
Similarly, grab bars and shower seats would not have to be installed at the time of construction provided that reinforcement has been installed in walls and located so as to permit their...
-
Definitions of residential facilities and transient lodging. (Section-by-Section Analysis)
Similarly, grab bars and shower seats would not have to be installed at the time of construction provided that reinforcement has been installed in walls and located so as to permit their...
- Aluminum Heavy Duty Wheels n' Heels® Metro Grating
- Aluminum Dove Tail Series Pressure-Locked Grating
-
902.1 General
Dining surfaces include, but are not limited to, bars, tables, lunch counters, and booths....
-
Single-User Toilet Rooms: No Side Transfer Space
Lavatory placement is limited by the rear gab bar, which should not overlap counter surfaces....
- Kompan, Inc. Vega GXY8017
- Seton EZ-Roll Sign Stanchion Systems - Parking Sign PP244
- Hill-Rom Sabina® II Mobile Lift
- Allegion LCN 1260 Series Surface Mounted Door Control