The system shall provide both audible and visual signals. Advisory 708.2 Audible and Visual Indicators. A light can be used to indicate visually that assistance is on the way....
Search Results "Fire and Safety Standard"
-
Audible and Visual Indicators: ADA Standard Section 708.2
-
Entry Points and Seats: ADA Standard Section 1008.4.4
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or...
-
Wall Depth and Length: ADA Standard Section 1009.4.3
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum. The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be...
-
Fishing Piers and Platforms: ADA Standard Section 1005
[See subsections ...]
-
Installation Height and Location: ADA Standard Section 703.4
Signs with tactile characters shall comply with 703.4.
-
Living and Dining Areas: ADA Standard Section 806.2.1
Living and dining areas shall be accessible.
-
Toilet and Bathing Rooms: ADA Standard Section 805.4
Toilet and bathing rooms that are provided as part of a patient or resident sleeping room shall comply with 603. Where provided, no fewer than one water closet, one lavatory, and one...
-
Sales and Service Counters: ADA Standard Section 904.4
Sales counters and service counters shall comply with 904.4.1 or 904.4.2. The accessible portion of the counter top shall extend the same depth as the sales or service counter top. ,...
-
Exercise Machines and Equipment: ADA Standard Section 1004
[See subsections ...]
-
Coat Hooks and Shelves: ADA Standard Section 803.5
Coat hooks provided within the room shall be located within one of the reach ranges specified in 308. Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum...
-
Load and Unload Areas: ADA Standard Section 1002.3
A turning space complying with 304.2 and 304.3 shall be provided in load and unload areas.
-
Toilet and Bathing Facilities: ADA Standard Section 807.2.4
Toilet facilities or bathing facilities that are provided as part of a cell shall comply with 603. Where provided, no fewer than one water closet, one lavatory, and one bathtub or...
-
Toilet and Bathing Facilities: ADA Standard Section 806.2.4
At least one bathroom that is provided as part of a guest room shall comply with 603. No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with...
-
2.4.2 Considerations of Manufacturers in Accessible MDE Design
These standards, regulations, and recommended practices provide details concerning the elements supporting the basic safety and essential performance of MDE....
-
Acknowledgements
Fraser, Senior Building Code Specialist, National Fire Protection Assoc., Inc. (NFPA) Kathy Gips, New England ADA Center Darlene Hemerka, J.D....
-
[2010 ADAS] 105.2.4 ICC/IBC
While typical elevators are not designed to be used during an emergency evacuation, evacuation elevators are designed with standby power and other features according to the elevator safety...
- American Standard Madera 1.28 gpf ADA Toilet with Exposed Manual Flush Valve System
- American Standard Madera 1.6 gpf ADA Toilet with Exposed Manual Flush Valve System
-
11B-504.8 Floor identification
Architects, Signage Consultants and Manufacturers having standard details showing one sign for both purposes are encouraged to change them permanently, indicating two separate and distinct...
- Allegion Von Duprin 98/99 Series Exit Devices
- Hager Companies 5400 Series - Standard Duty Surface Door Closer
- Big John Standard Toilet Seat Closed Front with Cover - 6W
- Salsbury Industries 61000 Series Single Tier Standard Metal Lockers
-
1.1.3.2 State-regulated buildings, structures, and applications
California State University, and to the extent permitted by California laws, buildings designed and constructed by the Regents of the University of California, and regulated by the Building Standards...