Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
Search Results "Head End Wall"
-
11B-505.10.3 Bottom extension at stairs
-
11B-810.6 Rail station signs
This means that signs can be placed well out of reach of Braille readers, even on parapet walls and on walls beyond barriers....
-
11B-810.6 Rail station signs
This means that signs can be placed well out of reach of Braille readers, even on parapet walls and on walls beyond barriers....
-
4.3.5.1 90-Degree Turn
These data are based on measurements of wheeled mobility users performing 90-degree turns in a hallway, built with mock walls. The outside wall of the hallway was fixed....
-
2. Other considerations when developing websites:
transcripts if sounds automatically play;Â provide a second, static copy of pages that are auto-refreshing or that require a timed-response;Â use titles, context, and other heading...
-
608 Shower Compartments
608.4) the location and operation of controls, faucets, and spray units (608.5) shower spray units and water temperature (608.6) a new exception for fixed shower heads...
-
709.5 Openings
The doors shall have head and jamb stops, astragals or rabbets at meeting edges and automatic-closing devices. Positive-latching devices are not required....
-
D. Sign Height
Does each accessible parking space have a post- or wall-mounted sign with the symbol of accessibility mounted high enough so the sign is visible when a vehicle is parked in the space?...
-
4.21.5 Controls
In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit shall be mounted on the side wall opposite the seat....
-
4.21.5 CONTROLS
In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit shall be mounted on the side wall opposite the seat....
-
1009.7.3 Openness
The sides other than the separation walls shall be not less than 50 percent open, and the open area shall be distributed so as to minimize the accumulation of smoke or toxic gases....
-
1009.7.3 Openness
The sides other than the separation walls shall be not less than 50 percent open, and the open area shall be distributed so as to minimize the accumulation of smoke or toxic gases....
-
II-7.3300 Seven-digit lines.
[Insert the following text at the end of this section, p. 42.]...
-
410.6 Doors and Gates
End doors and gates shall provide a clear width 32 inches (815 mm) minimum. Side doors and gates shall provide a clear width 42 inches (1065 mm) minimum....
-
11B-304.3.2 T-Shaped space
The space shall be permitted to include knee and toe clearance complying with Section 11B-306 only at the end of either the base or one arm. ...
-
11B-304.3.2 T-Shaped space
The space shall be permitted to include knee and toe clearance complying with Section 11B-306 only at the end of either the base or one arm....
- Willoughby Industries US-HC Cabinet Shower
- Spectrum Aquatics Traveler II XRC500 Pool Lift
- Willoughby Industries WAF-3300 AquaFount® Three Station Solid Surface Washfountain
- Willoughby Industries WAF-3603 AquaFount® Three Station Half Round 36" Solid Surface Deep Bowl Washfountain
- Willoughby Industries WAF-3606 AquaFount® Six Station Full Round 36" Solid Surface Deep Bowl Washfountain
-
Plan 6B: 12-Foot Wide Accessible Guest Room
Features include a transfer shower, water closet length (rim to rear wall) 24 inches maximum, comparable vanity, wardrobe, and door connecting to adjacent guest room....
-
Toe Clearance: ADA Standard Section 604.8.1.4
Section 604.8.1.4 covers the current ADA Standards for toe clearance at wheelchair accessible compartments.