Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
Search Results "Water Closet Clear Floor Space"
Commonly Searched Documents
-
11B-703.4.2 Location
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
- Figure 1009.5.2 Clear Deck Space at Transfer Platform – Drawing from the U.S. Access Board
-
General: ADA Standard Section 304.1
Section 304.1 of the ADA Standards covers information in the current ADA Standards for turning space.
-
1002.4.1 Floor or Ground Surface
1002.4.1 Floor or Ground Surface. The floor or ground surface of wheelchair spaces shall be stable and firm....
-
Storage [9.2.2(4)]
Storage [9.2.2(4)] At least one of each type of fixed or built-in storage facility (cabinets, shelves, closets, drawers) provided in accessible spaces must be accessible as specified...
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
- Zurn Industries Floor Access Cover
-
Storage: ADA Standard Section 225.2
Section 225.2 covers scoping requirements in the current ADA Standards for storage.
-
Bus Shelter Benches
The clear space within the shelter is required to accommodate wheelchair users....
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
The features that make this possible are: an accessible route to and through the room; an entry door with adequate clear width, maneuvering clearance, and accessible hardware;...
-
11B-607.6 Shower spray unit and water
Bathtub shower spray units shall deliver water that is 120°F (49°C) maximum. Advisory 11B-607.6 Shower spray unit and water....
- Visitability
-
Exposed Pipes and Surfaces: ADA Standard Section 606.5
Section 606.5 covers the current ADA Standards for exposed pipes and surfaces under lavatories and sinks.
-
11B-606.5 Exposed pipes and surfaces
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact....
-
Turning Space: ADA Standard Section 805.2
Turning space complying with 304 shall be provided within the room....
-
1002.4.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall be stable and firm....
-
1002.4.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall be stable and firm....
-
Attachment J: Access to Humboldt County Programs Housed in Others’ Facilities
Attachment J: Access to Humboldt County Programs Housed in Others’ Facilities
-
11B-225.2 Storage
Where storage is provided in accessible spaces, at least one of each type shall comply with Section 11B-811. Advisory 11B-225.2 Storage....
-
Wheelchair Storage Space: ADA Standard Section 1002.6.3
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
-
Seating [4.32.2] and Knee Clearance [4.32.3]
Seating [4.32.2] and Knee Clearance [4.32.3] Knee space at least 27 inches high is required for a depth of 19 inches....