Search Results "Water Closet Clear Floor Space"
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet Side View
- American Standard Madera 1.6 gpf ADA EverClean Toilet with Exposed Manual Flush Valve System Side View
-
Mansfield Toilet Erie Commercial Package CP-1301
Requires the Premium User plan or above. (Login or upgrade your account!)
-
4.1.6(4)(e)
Where alterations to existing facilities make strict compliance with 4.22 and 4.23 structurally impracticable, the addition of one "unisex" toilet per floor containing one water closet complying...
-
1011.1 General
All outdoor constructed features are required to comply with the provisions for clear ground space (1011.2) and operable parts (1011.3)....
-
Key Study findings:
. the 5th percentile or approximately 95% of the study sample) could transfer independently to a platform at a height that was within one inch of the mean wheelchair or scooter seat to floor...
- Figure 604.5.1 Side Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
-
11B-604.5 Grab bars
Grab bars for water closets shall comply with Section 11B-609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
Position [§305.5]
Position [§305.5] At most elements, clear floor or ground space can be positioned for either a forward or a side approach....
-
Wheelchair Passage Width [4.2.1] and Passing Space [4.2.2]
A minimum width of 30 inches is generally sufficient for stationary space. Additional clearance is needed for maneuvering and sway....
-
11B-604.5 Grab bars
Grab bars for water closets shall comply with Section 11B-609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
11B-604.5 Grab bars
Grab bars for water closets shall comply with Section 11B-609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
4.1.6(3)(e)(i)
(i) Where it is technically infeasible to comply with 4.22 or 4.23, the installation of at least one unisex toilet/bathroom per floor, located in the same area as existing toilet facilities...
-
R212.6 Benches
At least 50 percent, but no less than one, of benches at each location shall provide clear space complying with R404 adjacent to the bench....
-
1016.4 Passing Spaces
Outdoor recreation access routes with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 1016.4 at intervals of 200 feet (61 m) maximum. ...
-
1016.4 Passing Spaces
Outdoor recreation access routes with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 1016.4 at intervals of 200 feet (61 m) maximum....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-1008.2.4 Clear width
Accessible routes connecting play components shall provide a clear width complying with Section 11B-1008.2.4....
-
11B-1008.2.4 Clear width
Accessible routes connecting play components shall provide a clear width complying with Section 11B-1008.2.4....
-
Features of an Accessible Examination Room
A clear floor space, 30” X 48” minimum, adjacent to the exam table and adjoining accessible route make it possible to do a side transfer. 2....
-
4.22.3* Clear Floor Space
An unobstructed turning space complying with 4.2.3 shall be provided within an accessible toilet room....
- Sioux Chief FullFlush™ Offset Flange 889-AOM