appropriate for the gripping surfaces of transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
Search Results "Shower Seat"
Commonly Searched Documents
-
Cross Section of Gripping Surfaces
-
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND PALACE SPORTS AND ENTERTAINMENT, LLC, REGARDING THE PALACE OF AUBURN HILLS
[See subsections ...]
-
Clear Space Evaluation
Increasing the width of the clear floor space an additional 12 inches to 72 inches would accommodate 75-77% of users who would be expected to transfer higher or lower than their seat to...
-
5.8.2.5 Toe Height Recommendation
However, it is important to provide extra toe space for patients who are seated close to the ground but have their footrests positioned at more of an angle....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface,...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface,...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface,...
-
609.4 Position of Grab Bars
609.4 Position of Grab Bars. Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface,...
-
11B-609.4 Position of grab bars
11B-609.4 Position of grab bars. Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface,...
-
(1) Adjustability: Minimum High Transfer Height
Seat heights for males were typically higher than for females....
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
- Neo-Metro Urban Stainless Steel Toilet 8950-3-ADA-PFS
- Delta Elongated Toilet C43902-WH
- Mansfield Toilet ADA Commercial Package CP-1313
- Mansfield Erie Commercial Package Toilet CP-1301
- TOTO® CT705ELN Commercial Flushometer High Efficiency Toilet
- Delta Elongated Toilet C43904-WH
- Delta Elongated Concealed Trapway Toilet C43906-WH
-
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations
and Toe Clearance Recommendations under Breast Platform Recommendations Description: The knee and toe clearance under the breast platform applies to mammography equipment for patients seated...
-
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
Clearances Around Gripping Surfaces
gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
Whitehall Mfg. 24" Grab Bar L-Shaped Closure Plate
Requires the Premium User plan or above. (Login or upgrade your account!)