Search Results "Vertical Actuation Bar"
Commonly Searched Documents
- Bradley 812 Grab Bars 1 1/2" Tube Concealed Ends Various Sizes Model
-
407.12.1 Vertical Reference Plane (Section-by-Section Analysis)
407.12.1 Vertical Reference Plane (Section-by-Section Analysis) This section proposes that the positioning of operable parts for side reaches and forward reaches be determined with respect...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
609 Grab Bars
609 Grab Bars...
-
6.9 Tread Obstacles
Obstacles on beach access routes and their related resting intervals shall not exceed 1 inch (25 mm) in height measured vertically to the highest point....
-
Grab bars
Grab bars: Section 609 of the ADA-ABA standards [7] includes provisions for grab bars in areas where transfers are expected....
-
GRAB BAR
GRAB BAR. [DSA-AC & HCD 1-AC] A bar for the purpose of being grasped by the hand for support. Advisory Definition of GRAB BAR. ...
-
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]...
-
11B-1009.4.5 Grab bars
Where one grab bar is provided, clearance shall be 24 inches (610 mm) minimum on both sides of the grab bar....
-
Control End Wall: ADA Standard Section 607.4.2.2
Section 607.4.2.2 covers the current ADA Standards for grab bars on the control end of bathtubs without permanent seats.
-
Head End Wall: ADA Standard Section 607.4.2.3
Section 607.4.2.3 covers the current ADA Standards for grab bars on the head end wall of bathtubs without permanent seats.
-
Control End Wall: ADA Standard Section 607.4.1.2
Section 607.4.1.2 covers the current ADA Standards for grab bars on the control end of bathtubs with permanent seats.
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. ...
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
- Bradley Grab Bars 1 1/4" with Concealed Mounting 832
- Bradley Grab Bars 1 1/4" with Exposed Mounting 837
-
11B-1009.5.7 Grab bars
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided....
-
11B-1009.5.7 Grab bars
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided....
-
11B-1009.5.7 Grab bars
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided....
-
GRAB BAR
[DSA-AC & HCD 1-AC] A bar for the purpose of being grasped by the hand for support. Advisory Definition of GRAB BAR....