Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
Search Results "Vertical Actuation Bar"
Commonly Searched Documents
-
11B-812.4 Vertical clearance
-
§ 38.107(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
Grab Bars: ADA Standard Section 604.9.4
Section 604.9.4 covers the current ADA Standards for grab bars for children's use water closets.
-
11B-604.8.2.3 Grab bars
Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
-
R302.7.1 Vertical Alignment
R302.7.1 Vertical Alignment....
-
11B-609.6 Fittings
Grab bars shall not rotate within their fittings....
-
1607.9.2 Grab bars, shower seats and accessible benches
Grab bars, shower seats and accessible benches shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower...
-
Side Wall: ADA Standard Section 604.5.1
Section 604.5.1 covers the current ADA Standards for side wall grab bars that are used for water closets.
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
Grab Bars
The most common location for grab bars is in restrooms....
-
Back Wall: ADA Standard Section 607.4.1.1
Section 607.4.1.1 covers the current ADA Standards for back wall grab bars in bathtubs with permanent seats.
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
Back Wall: ADA Standard Section 607.4.2.1
Section 607.4.2.1 covers the current ADA Standards for back wall grab bars in bathtubs without permanent seats.
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
1607A.9.2 Grab bars, shower seats and accessible benches
Grab bars, shower seats and accessible benches shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower...
-
11B-212 Kitchens, kitchenettes, wet bars and sinks
212 Kitchens, Kitchenettes, and Sinks ETA Editor’s Note The CBC includes wet bars. Therefore, the CBC is more inclusive....
-
American Specialties Concealed Mounting Grab Bar 3100-Series
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Grab Bars: ADA Standard Section 608.3
Section 608.3 covers the current ADA Standards for grab bars in shower compartments.
- Inpro Corporation Endurant® Stainless Steel Straight Grab Bar
-
Grab Bars: ADA Standard Section 607.4
Section 607.4 covers the current ADA Standards for bathtub grab bars.
-
Clear Width [4.13.5] and Vertical Clearance
Clear Width [4.13.5] and Vertical Clearance The clear width of the opening is measured from the face of the door in a 90 degrees open position to the opposite stop....
- American Specialties Snap Flange Concealed Mounting Grab Bar 3700-Series
- 604.5.2 Rear Wall Grab Bar Location