Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1....
Search Results "Sink Depth"
Commonly Searched Documents
-
606.3 Height
-
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1....
-
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground....
-
Faucets: ADA Standard Section 606.4
Section 606.4 covers the current ADA Standards for the faucet controls of lavatories and sinks.
-
11B-606.4 Faucets
Controls for faucets shall comply with Section 11B-309. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-212.1 General
Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. [2010 ADA Standards] 212.1 General....
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
for sinks in transient lodging....
-
11B-212.1 General
Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. ...
-
11B-212.1 General
Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. ...
-
504.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
-
504.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
-
504.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
-
LAVATORY
(As differentiated from the definition of “Sink”.)...
-
LAVATORY
(As differentiated from the definition of “Sink”.)...
-
11B-308.3.1 Unobstructed
Exceptions: An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum....
-
4.34.6 KITCHENS
Accessible or adaptable kitchens and their components shall be on an accessible route and shall comply with the requirements of 4.34.6.
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
Unobstructed: ADA Standard Section 308.3.1
Section 308.3.1 covers the current ADA Standards for unobstructed side reach.
- Figure 1009.5.4 Transfer Steps – Drawing from the U.S. Access Board
-
11B-805.2.1 Hand washing fixtures
Hand washing fixtures shall comply with Section 11B-606.
-
Obstructed Reach Depth
Obstructed Reach Depth...
-
11B-604 Water closets and toilet compartments
INTERPRETATION CBC Section 1224.14.2.7 requires the provision of a flushing-rim clinical sink in the soiled utility room of a nursing unit....
-
11B-809.9.7 Exposed pipes and surfaces
Exposed water supply and drain pipes under sinks and lavatories shall comply with Section 11B-606.5....