stories above the level of exit discharge, not less than one required accessible means of egress shall include an elevator complying with Section 1009.4....
Search Results "Exit Ramp"
-
1009.2.1 Elevators required
-
1009.2.1 Elevators required
In buildings where a required accessible floor or occupied roof is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall...
-
Doorways: ADA Standard Section 405.7.5
Section 405.7.5 covers the current ADA Standards for doorway maneuvering clearance at ramp landings.
-
11B-207 Accessible means of egress
[See subsections ...]
-
1011.4 Raised character and Braille exit signs
1011.4 Raised character and Braille exit signs. Tactile exit signs shall be required at the following locations:...
-
1013.4 Raised character and Braille exit signs
1013.4 Raised character and Braille exit signs. Tactile exit signs shall be required at the following locations:...
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
1011.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1011.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
-
1013.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1013.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
-
Slope: ADA Standard Section 405.7.1
Section 405.7.1 covers the current ADA Standards for the slope in ramp landings.
-
11B-405.9 Edge protection
Edge protection complying with Section 11B-405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. [2010 ADA Standards] 405.9 Edge Protection....
-
11B-405.9 Edge protection
Edge protection complying with Section 11B-405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. [2010 ADA Standards] 405.9 Edge Protection....
-
Ramp
Ramp - A walking surface that has a running slope of greater than 1:20....
-
Edge Protection: ADA Standard Section 405.9
Section 405.9 covers the current ADA Standards for edge protection at ramps.
- Figure 405.7 Ramp Landings – Drawing from the U.S. Access Board
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings at perpendicular curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings at perpendicular curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
11B-406.3.1 Slope
The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12....
-
11B-406.3.1 Slope
The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12....
-
1009.2 Continuity and components
the level of exit discharge....
-
Raised character and Braille exit signs
Raised character and Braille exit signs shall comply with Chapter 11A, Section 1143A or Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5....
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...