Exceptions: Areas of refuge are not required at exit access stairways where two-way communication is provided at the elevator landing in accordance with Section 1009.8....
Search Results "Exit Ramp"
Commonly Searched Documents
-
1009.3.3 Area of Refuge
-
11B-406.5.9 Clear space at diagonal curb ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1219 mm) minimum outside active traffic lanes of the roadway....
-
11B-247.1.2.2 Curb ramps
Curb ramps shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.2....
- Handi-Ramp Galvanized Steel Ramps
-
Rise: ADA Standard Section 405.6
Section 405.6 covers the current ADA Standards for the rise requirements of ramps.
-
11B-405.6 Rise
The rise for any ramp run shall be 30 inches (762 mm) maximum....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
Exit Stairway Enclosures [IBC §1007.3 and 1019 (2003), §1003.2.13.2 and 1005.3.2 (2000)]
The IBC contains requirements for exit stairway enclosures that address fire-resistance and smoke protection, stairways and handrails, signs, and other features....
- EZ-ACCESS GATEWAY™ Solid Surface Portable Ramp
-
1003.2.13.7.2 Exterior exit stairway
Section 1003.2.13.7.2 Add new sections as follows: (E22-00) 1003.2.13.7.2 Exterior exit stairway. ...
-
SECTION 1011 EXIT SIGNS
SECTION 1011 EXIT SIGNS...
-
Means of Egress
A means of egress is comprised of exit access, exit, and exit discharge....
-
Approach, Enter, and Exit
Approach, Enter, and Exit Employee work areas are required by TAS 203.9 to be designed and constructed so that individuals with disabilities can approach, enter, and exit the work area...
-
SECTION 1012 RAMPS
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
405 Ramps
Section 405 provides technical criteria for ramps....
-
11B-406.5.10 Diagonal curb ramps
Diagonal or corner type curb ramps are perpendicular or parallel curb ramps that are oriented diagonally at an intersection....
-
Ramps [4.8]
Where the running slope of an accessible route is more than 5%, it is considered a ramp. Generally, changes in level up to 6 inches can be treated as a curb ramp....
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator...
-
9. Exterior Ramps
9. ...do the exterior ramps have the following features: a. top and bottom landings that are level, at least as wide as the ramp they serve, and at least 60" long to allow for adequate...
-
11B-207 Accessible means of egress
[See subsections ...]
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
1011.4 Raised character and Braille exit signs
1011.4 Raised character and Braille exit signs. Tactile exit signs shall be required at the following locations:...
-
1013.4 Raised character and Braille exit signs
1013.4 Raised character and Braille exit signs. Tactile exit signs shall be required at the following locations:...
-
1011.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1011.1 shall be identified by a tactile exit sign with the word, “EXIT.”...