A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones...
Search Results "Approach"
Commonly Searched Documents
-
4.31.2 CLEAR FLOOR OR GROUND SPACE
-
4.5.2.1 Forward Approach
The clear floor or ground space for a forward approach shall be 36 inches (915 mm) by 48 inches (1220 mm)....
-
4.5.2.2 Side Approach
The clear floor or ground space for a side approach shall be 30 inches (760 mm) by 60 inches (1525 mm)....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
4.31.3* MOUNTING HEIGHT
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.
-
4.19.3 Clear Floor Space
A clear floor space 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a lavatory to allow forward approach....
-
4.19.3 CLEAR FLOOR SPACE
A clear floor space 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a lavatory to allow forward approach....
-
Approach: ADA Standard Section 904.2
Advisory 904.2 Approach....
-
Approach: ADA Standard Section 802.1.4
Fig. 46(b)] Advisory 802.1.4 Approach....
-
4.1.1(3) Areas Used Only by Employees as Work Areas
Areas that are used only as work areas shall be designed and constructed so that individuals with disabilities can approach, enter, and exit the areas....
-
Range or Cooktop: ADA Standard Section 804.6.4
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
Clear Floor or Ground Space: ADA Standard Section 902.2
A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided....
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided....
-
Forward Approach
Forward Approach Knee and toe clearances specified for lavatories in 4.19, which recognize space for plumbing (see page 75), can be applied to sinks....
-
4.18.3 Clear Floor Space
A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall be provided in front of urinals to allow forward approach....
-
4.18.3 CLEAR FLOOR SPACE
A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall be provided in front of urinals to allow forward approach....
-
Maximum Depth: ADA Standard Section 306.2.2
Section 306.2.2 covers the current ADA Standards for the maximum depth for toe clearance.
-
Minimum Required Depth: ADA Standard Section 306.3.3
Section 306.3.3 covers the current ADA Standards for the minimum required depth for knee clearance.
-
Maximum Depth: ADA Standard Section 306.3.2
Section 306.3.2 covers the current ADA Standards for the maximum depth for knee clearance.
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...