The lift may be marked to indicate a preferred standing position....
Search Results "Positioning Support"
-
§ 38.125(b)(12) Use by standees
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
§ 38.159(b)(12) Use by standees
The platform may be marked to indicate a preferred standing position....
-
11B-807.2.3 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
§ 38.83(b)(12) Use by standees
The lift may be marked to indicate a preferred standing position....
-
11B-807.2.3 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
- Delta 3-Setting 2-Port Diverter Trim T11859
- Delta 3-Setting 2-Port Diverter Trim T11861
- iLove Stories of Independence: Todd Stabelfeldt
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting...
-
§ 1194.2(a)(2)
(2) When procuring a product, if an agency determines that compliance with any provision of this part imposes an undue burden, the documentation by the agency supporting the procurement...
-
4.26.3(3)
Shear force induced in a fastener or mounting device from the application of 250 lbf (1112N) shall be less than the allowable lateral load of either the fastener or mounting device or the supporting...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device, or supporting...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting...
-
§382.133(d)(1)
(1) A POC, a ventilator, a respirator or a continuous positive airway pressure machine that displays a manufacturer's label according to FAA requirements in circumstances where requirements...
-
4. Faucet Controls
Are the faucet controls and shower wand positioned on the wall along the side of the shower seat so they are operable from the folding shower seat or from the shower wheelchair?...
-
11B-604.9.3 Height
Seats shall not be sprung to return to a lifted position....
-
Free-Standing Overhead Lifts
Free-Standing Overhead Lifts Another type of overhead lift is supported from a frame that rests on the floor....
-
410.6 Real-Time Text Functionality (Section-by-Section Analysis)
Proposed 410.6 would require that, where ICT supports real-time voice communication, it must also support RTT functionality....
-
Define "animal" or what qualifies certain species as "service animals." (Section-by-Section Analysis)
The American Veterinary Medical Association (AVMA) issued a position statement against the use of monkeys as service animals, stating, "[t]he AVMA does not support the use of nonhuman primates...
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers. ...
-
4.26.3(4)
a direct tension force of 250 lbf (1112N) plus the maximum moment from the application of 250 lbf (1112N) shall be less than the allowable withdrawal load between the fastener and the supporting...
-
1009.2.4 Seat Height
lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the raised (load) position...
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.