6.9
-
Attachment E
The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach...
-
608.2.1 Transfer Type Shower Compartments
Clearance of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided....
-
804.3.1 Clear Floor or Ground Space
conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish floor extends under the cabinetry; and (c) the walls...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-804.3.1 Clear floor or ground space
conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish floor extends under the cabinetry; and (c) the walls...
-
Size and Clearances [4.21.2]
Recommendations: Consider additional clear floor space beyond the control wall to facilitate the reach to controls....
-
Exposed Pipes and Surfaces [4.19.4]
The P-trap may also be installed parallel to the wall so that it is located outside the knee/toe space....
-
General [5.1]/ Access Aisles [5.3]
The required clear width (36 inches minimum) is specified for the clearance between the edges of fixed tables or between table edges and walls....
-
F213.1 General
Some pit toilets do not have walls and would not be able to comply with the technical requirements for toilet facilities such as providing grab bars at toilet fixtures....
-
Doors and Gates in Series [§404.2.6]
Recommendation: Wheelchair space 30” min. by 48” min. beyond the swing of a door in other configurations, such as vestibules with doors on adjacent walls, will provide room to clear one...
-
11B-804.3.1 Clear floor or ground space
conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish floor extends under the cabinetry; and (c) the walls...
-
11B-804.3.1 Clear floor or ground space
met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish floor extends under the cabinetry; and (c) the walls...
-
Mounting Height and Location
At double doors with two active leafs, signs are to be located on the right-hand side or, if no wall space is available, on the nearest adjacent wall....
-
Q2.) What are the types of “field conditions” that were anticipated where the advisory says “tolerances recognized by this provision include those for field conditions”?
For example, a skilled brick mason cannot lay a perfectly vertical and straight wall. A skilled tile layer cannot create a perfectly flat wall behind a toilet room grab bar. ...
-
Accessible
Housing Act refers to design features that include both the minimal "accessibility" features required to be built into the unit, and the "adaptable" feature of reinforcement for bathroom walls...
-
239.3 Miniature Golf Course Configuration
Where only the minimum 50 percent of the holes are accessible, an accessible route from the last accessible hole to the course exit or entrance must not require travel back through other...
-
11B-239.3 Miniature golf course configuration
Where only the minimum 50 percent of the holes are accessible, an accessible route from the last accessible hole to the course exit or entrance must not require travel back through other...
-
II-5.1000 General.
[Insert the following text before the question, "Can back doors . . . ?" p. 22.]...
-
F239.3 Miniature Golf Course Configuration
Where only the minimum 50 percent of the holes are accessible, an accessible route from the last accessible hole to the course exit or entrance must not require travel back through other...
-
Accessible Routes
When not all holes are accessible, a player cannot be required to double back through holes to exit....
-
239.3 Miniature Golf Course Configuration
Where only the minimum 50 percent of the holes are accessible, an accessible route from the last accessible hole to the course exit or entrance must not require travel back through other...
-
206.3 Location
Additionally, accessible vertical interior circulation must be in the same area as stairs and escalators, not isolated in the back of the facility....