Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
Search Results "Assurances from Contractors"
Commonly Searched Documents
-
11B-703.5.4 Character proportions
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
- Allegion aptiQ Mullion and Mini-Mullion Reader Installation
- Installation Process of Genesis Vertical Platform Wheelchair Lift - Garaventa Lift
-
Doors, Doorways, and Gates
of a provision covering doors and doorways in inaccessible transient lodging guest rooms in section 206.5.3 (located at 224.1.2 in the proposed rule) addition of a new exception from...
-
3. Modified Theaters
It is understood that seating row numbers are from row locations as they exist at the time that this Consent Order is entered and that in some cases, modifications will result in removal...
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
§382.91(b)
provision of assistance requested by or on behalf of a passenger with a disability, or offered by carrier or airport operator personnel and accepted by a passenger with a disability, in moving from...
-
CHAPTER 10 MEANS OF EGRESS
CHAPTER 10 MEANS OF EGRESS ETA Editor's Note Sections from California Building Code Chapter 10 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted...
-
Paragraph (g) Availability of audio cutoff (Section-by-Section Analysis)
Comments from persons with hearing impairments supported this provision. However, some comments from both people with disabilities and manufacturers misunderstood this requirement....
-
Cross Slope
Measurements, absent live loads, are to be made from a static condition (i.e., absence of movement that results from wind, waves, etc.)....
-
Dispersion
Dispersion Anglers who can stand are able to fish from any part of a pier or platform and change locations....
-
607.4.1.1 Back Wall
Each grab bar shall be installed 15 inches (380 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
CHAPTER 9 FIRE PROTECTION SYSTEMS
CHAPTER 9 FIRE PROTECTION SYSTEMS ETA Editor's Note Sections from California Building Code Chapter 9 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted...
-
1134A.6, Item 5
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
-
403.1 General (Section-by-Section Analysis)
403.1 General (Section-by-Section Analysis) This section proposes to prohibit biometrics from being the only means for user identification or control unless at least two different biometric...
-
Door Closers [4.13.10]
ADAAG requires that the sweep period of the closer be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 inches from the latch...
-
Protruding Objects [4.31.4]
., 27 inches high from the floor), can be a hazard to people with vision impairments....
-
Recessed Doors and Gates [§404.2.4.3]
If any obstruction within 18” of the latch side projects more than 8” from the face of a door or gate, maneuvering clearances for a forward approach must be provided....
-
1134A.6, Item 5
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
-
§ 37.123(e)(3)(ii)
interaction of such barriers with an individual's specific impairment-related condition may form a basis for eligibility under this paragraph, if the effect is to prevent the individual from...
-
11B-703.5.4 Character proportions