Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
Search Results "Assurances from Contractors"
-
11B-705.1.2.2.2 Parallel curb ramps
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
11B-809.6 Residential dwelling units with adaptable features
ETA Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Reference to “multifamily” in...
-
§ 36.406(f)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
503.5 Vertical Clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
-
Floor Height [1013.4]
If the tent platform floor is raised above grade, the floor height must be no more than 19 inches when measured from the clear ground space to the tent platform surface....
-
§ 36.406(f)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
§ 35.151(g)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
503.5 Vertical Clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
-
Locker Rooms
Locker Rooms Recommendations: Benches of the required size (24 inches deep and at least 48 inches long) can be integrated with lockers so that back support is provided from a wall....
-
§ 35.151(g)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
§ 38.29(f)
(f) For vehicles in excess of 22 feet in length, the minimum interior height along the path from the lift to the securement location shall be 68 inches....
-
11B.707.7.1.3 Horizontally mounted display screen
Where display screens are mounted tipped away from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be...
-
Medical Diagnostic Equipment: ADA Standard Section 5.
Review the updated information on the revisions to the ADA Standards regarding medical diagnostic equipment.
-
3. Medical Diagnostic Equipment
From the Board’s website: “The Access Board has issued a notice of proposed rulemaking (NPRM) to remove the sunset provisions in the our existing accessibility standards for medical diagnostic...
-
3. Medical Diagnostic Equipment
From the Board’s website: “The Access Board has issued a notice of proposed rulemaking (NPRM) to remove the sunset provisions in the our existing accessibility standards for medical diagnostic...
-
11B-610.3 Shower compartment seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (76 mm) of the compartment entry....
-
Viewing Scopes [1011.2, 1011.3, and 1011.8]
When viewing scopes are provided, separate viewing scopes must be provided for use from a standing position and from a seated position....
-
802.1.3 Depth
Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum....
-
§8.4(c)(1)
(1) Non-handicapped persons may be excluded from the benefits of a program if the program is limited by Federal statute or executive order to individuals with handicaps....
-
§100.10(a)(2)
Prohibit a private club, not in fact open to the public, which, incident to its primary purpose or purposes, provides lodgings which it owns or operates for other than a commercial purpose, from...
-
M303.2.3 Depth
Where wheelchair spaces can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum....
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform...