“Clearance Space Envelopes of Wheeled Mobility Device Users for Computer Workstations”. Proceedings of the Human Factors and Ergonomics Society Annual Meeting 2012....
Search Results "Clearance in Base"
Commonly Searched Documents
-
References:
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
Recessed Lavatories
In-swinging doors must clear fixture clearances and door clearances must clear the water closet fixture (verify toilet length)....
-
Water Closet Clear Floor Space in Toilet Compartments
Water closets not in compartments require clearance that is at least 60 inches wide and 56 inches deep....
-
Other Boxes: ADA Standard Section 221.2.1.3
Section 221.2.1.3 covers scoping requirements in the current ADA Standards for wheelchair spaces at other boxes not covered under 221.2.1.3.
-
Boat Slips: ADA Standard Section 235.2
Section 235.2 covers scoping requirements in the current ADA Standards for boat slips.
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
§ 38.25(c) Door height
For vehicles in excess of 22 feet in length, the overhead clearance between the top of the door opening and the raised lift platform, or highest point of a ramp, shall be a minimum of 68...
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
Water Closet Clear Floor Space
Clearance requirements for water closets are covered in section 604.3....
-
11B-806.2.3.1 Personal lift device floor space
ETA Editor's Note The clearance prescribed for a personal lift device at CBC 11B-806.2.3.1 is not required by 2010 ADA Standards....
-
TEXT TELEPHONE
[DSA-AC] Machinery or equipment that employs interactive text-based communications through the transmission of coded signals across the standard telephone network....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
Clear Floor Space [4.16.2]
amount of space required at an accessible toilet, not the minimum room size, which must also include turning space, clear floor space at other provided fixtures, door swing and maneuvering clearance...
-
Non-Tactile Signage
) · based on viewing distance · 3" min for overhead signs Braille · grade II required N/A Pictograms where provided: · 6" min. field height...
-
RECOMMENDATIONS
RECOMMENDATIONS Based on the conclusions above, two avenues of attack are recommended....
-
Section 6.0 Conclusions
None of the standards reviewed had a comprehensive and explicit approach to evidence based practice. 5....
-
4.3.5.3 180-degree turn around an obstacle
When the entry and egress aisles are less than this width, the 360-degree turn clearances should be provided at the turning area....
-
Recessed Objects
Elements, such as wheelchair accessible drinking fountains, must provide a knee clearance of at least 27”....
-
Clear Width: ADA Standard Section 404.3.1
Section 404.3.1 covers the current ADA Standards for clear width at automatic and power-assisted doors and gates.
-
Minimum Number: ADA Standard Section 208.2
Section 208.2 of the ADA Standards coversscoping requirements in the most current ADA Standards for the minimum number of parking spaces required.
- Selecting a Kitchen Faucet: Faucet Function and Spray
-
11B-504.3 Open risers
Exceptions: On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the tread....
-
Floor and Ground Surfaces
apply to: interior and exterior accessible routes, including walking surfaces, ramps, elevators, and lifts stairways that are part of a means of egress required clearances...