braille floor identification signs that comply with Chapter 11A, Section 1143A or Chapter 11B shall be located at the landing of each floor level, placed adjacent to the door on the latch side...
Search Results "Side Light"
-
1023.9 Stairway identification signs
-
1023.9 Stairway identification signs
braille floor identification signs that comply with Chapter 11A, Section 1143A or Chapter 11B shall be located at the landing of each floor level, placed adjacent to the door on the latch side...
- DeafSpace Project
-
Guest Rooms and In-Room Guest Services
switches and lighting, closet, suitcase stand, and telephone....
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
Is front-in only or angled parking prohibited for accessible parking spaces?
However, where van spaces are angled, the Standards require the access aisle to be located on the passenger side which is the side where vehicle ramps and lifts are typically deployed....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
Can van spaces required for a parking garage be located in a surface lot instead?
Open lots do not provide the same level of protection, security, and lighting as garage parking....
-
Can accessible spaces required for one parking facility be located in another one instead?
The term “user convenience” applies to factors such as protection from the weather, security, lighting, and comparative maintenance....
-
§ 37.83(a)(2)
(2) Purchases or leases a light or rapid rail vehicle which has been remanufactured so as to extend its useful life for five years or more, where the purchase or lease occurs after August...
- Allegion Falcon SC90 Series Surface Mounted Door Control
-
A4.15.2 Spout Height
Two drinking fountains, mounted side by side or on a single post, are usable by people with disabilities and people who find it difficult to bend over....
-
608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the...
-
F231.4.1 Cubicles and Counters
At least 5 percent, but no fewer than one, of cubicles shall comply with 902 on both the visitor and detainee sides....
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
231.4.1 Cubicles and Counters
At least 5 percent, but no fewer than one, of cubicles shall comply with 902 on both the visitor and detainee sides....
-
608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the...
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....