(6) Platform surface. The lift platform surface shall be free of any protrusions over 1/4 inch high and shall be slip resistant. The lift platform shall have a minimum clear width of...
Search Results "Rail System"
Commonly Searched Documents
-
§ 38.83(b)(6) Platform surface
-
§ 38.93(d)(4) Exception
(4) Exception. Retrofitted vehicles shall be coordinated with the platform in new and key stations such that the horizontal gap shall be no greater than 4 inches and the height of...
-
§ 38.95(b)(8) Platform entrance ramp
(8) Platform entrance ramp. The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches,...
-
2.1.2 Standards
2.1.2 Standards There are no national US standards that define the required performance of IL systems....
- STI Stopper® Emergency Station, Push, Turn-to-Reset SS-2001E Fire Alarm
- Door King Inc. VoIP Integration for Entry and Access Control Systems
-
Visible Alarms
Section 215.3 of the 2010 Standards provides that where employee work areas in newly constructed facilities have audible alarm coverage they are required to have wiring systems that are...
-
4. Obstructions
Fixed route operators would not have to establish flag stop or route-deviation policies, as these would be fundamental alterations to a fixed route system rather than reasonable modifications...
-
6. RECEIVERS AND COUPLERS: RECOMMENDATIONS
COUPLERS: RECOMMENDATIONS When hard of hearing people use an ALS, they are not usually concerned with the characteristics of the installation and transmission process of the various systems...
-
Accessible Lodging Factsheet
Many of these revisions apply to Places of Lodging such as new requirements for reservation systems, and revised and new standards for facility access [28 C.F.R. §§ 36.104, 36.302(e), 36.406...
-
1009.7.4 Stairways
Exception: The clear width of 48 inches (1220 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed in accordance...
-
1007.7.6 Stairway
Exception: The clear width of 48 inches (1219 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed in accordance...
-
1009.7.4 Stairways
Exception: The minimum clear width of 48 inches (1220 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed...
- Hollaender Manufacturing Company ADA Railing Systems
-
Audio Visual Components
Find out in advance if your facility has any assistive listening systems or devices available, how the meeting room is wired and equipped for sound amplification, and if there are additional...
-
10.4.1(5)
(5) Baggage check-in and retrieval systems shall be on an accessible route complying with 4.3, and shall have space immediately adjacent complying with 4.2.4....
-
§382.85 What seating accommodations must carriers make to passengers in circumstances not covered by §382.81 (a) through (d)?
As a carrier, you must provide the following seating accommodations to a passenger who self-identifies as having a disability other than one in the four categories listed in §382.81...
-
Paragraph (h) Non-interference with hearing technologies (Section-by-Section Analysis)
Paragraph (h) Non-interference with hearing technologies (Section-by-Section Analysis) Comment. Persons with hearing impairments uniformly supported this provision. Manufacturers,...
-
382.85 What seating accommodations must carriers make to passengers in circumstances not covered by section 382.81 (a) through (d)?
382.85 What seating accommodations must carriers make to passengers in circumstances not covered by section 382.81 (a) through (d)? Carriers must provide a seat that will accommodate...
-
1007.8.1.1 Visible communication method
1007.8.1.1 Visible communication method. [DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 _|Operable Parts|_ in the area of refuge shall...
-
Is a transportation operator required to procure vehicles with lifts that have a design load of more than 600 pounds?
No. 49 CFR Part 38 continues to require that lifts have a minimum design load of 600 pounds and that the lift platform accommodate a wheelchair measuring 30 inches by 48...
-
Securement
[See subsections ...]
-
Is a transportation operator required to procure vehicles with lifts that have a design load of more than 600 pounds?
No. 49 CFR Part 38 continues to require that lifts have a minimum design load of 600 pounds and that the lift platform accommodate a wheelchair measuring 30 inches by 48 inches....
-
Is a transportation operator required to carry these “overweight” wheelchairs?
Some wheelchairs weigh more than 600 pounds when occupied, and the design load of the lifts on our vehicles is 800 pounds. Is a transportation operator required to carry these...