Figure 28 (section 4.16) provides minimum clear floor space dimensions for toilets in accessible “unisex” toilet rooms....
Search Results "Floor Designation"
Commonly Searched Documents
-
A4.22.3 Clear Floor Space
-
24 CFR Part 100—Supplement to Notice of Fair Housing Accessibility Guidelines: Questions and Answers about the Guidelines
technical guidance on how to comply with the accessibility requirements of the Fair Housing Amendments Act of 1988 (Fair Housing Act) that are applicable to certain multifamily dwellings designed...
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided....
-
407.4.1 Car Dimensions
EXCEPTION: Existing elevator car configurations that provide a clear floor area of 16 square feet (1.5 m2) minimum and also provide an inside clear depth 54 inches (1370 mm) minimum and...
-
B. Slopes
[ADA Stds. 4.8.4] Yes __ No __ N/A __ Comments: ___________________________________________ ...for corridors into which at least one door swings, is there at least 54" clear floor...
-
Mats
requirements for fixed carpeting, have firm tapered edges for smooth transitions, be firm enough to minimize buckling or rolling and have an underside material or texture that grips the floor...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
- Inpro Corporation JointMaster® 925 Fire Barrier System Expansion Joint Systems
-
407.4.1 Car Dimensions
EXCEPTION: Existing elevator car configurations that provide a clear floor area of 16 square feet (1.5 m2) minimum and also provide an inside clear depth 54 inches (1370 mm) minimum and...
-
1133A.4.1, Item 4
Finished flooring shall be extended to the wall beneath the sink and work surface. Exceptions: 1....
-
407.4.1 Car Dimensions
[ECTCR UFAS 4.10.9, Fig. 22] EXCEPTION: Existing elevator car configurations that provide a clear floor area of 16 square feet (1.5 m2) minimum and also provide an inside clear depth...
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
-
Space Allowance and Reach Ranges [4.2]
They can also provide guidance on aspects of design not specifically covered in the ADAAG, such as standard eye level range (43-51 inches) and the design and height of elements viewed up...
-
§ 38.159(c)(5) Slope
If the height of the vehicle floor from which the ramp is deployed is 3 inches (75 mm) or less above a 6 inch (150 mm) curb, a maximum slope of 1:4 is permitted; if the height of the vehicle...
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
-
Trailhead Information Signs [F216.13 and 1017.10]
When a new trail information sign is provided at the trailhead on a newly constructed or altered trail designed for use by hikers or pedestrians, the sign must provide information about...
-
1. PURPOSE
These standards are to be applied during the design, construction, and alteration of buildings and facilities to the extent required by the Architectural Barriers Act of 1968, as amended...
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture....
-
606.2 Clear Floor Space
606.2 Clear Floor Space. A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
Fixtures
Fixtures TAS 604.3.2 also allows the clear floor space and clearances required at other “fixtures” to overlap the water closet clearance....
-
Finish and Contrast: ADA Standard Section 703.5.1
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...