(1) Installing ramps;...
Search Results "Curb Ramp Width"
-
§ 36.304(b)(1)
-
T502.4 Doorways with Steps on Over-the-Road Buses
On over-the-road buses, doorways with steps shall provide an opening with a clear width of 30 inches (760 mm) minimum. Exceptions: 1....
-
§ 38.93(b) Passageways
In cars where such doorways require passage through a vestibule, such vestibule shall have a minimum width of 42 inches. (See Fig. 3.)...
-
3.1.4.2 Width of RV Campsite and Dump Station Vehicle Parking Areas
The 20-foot width requirement applies only to the RV parking area and does not apply to the driveway of a parking spur or dump station. Exception....
-
11B-405.3 Cross slope
Cross slope of ramp runs shall not be steeper than 1:48. [2010 ADAS] Advisory 405.3 Cross Slope. Cross slope is the slope of the surface perpendicular to the direction of travel....
-
11B-405.3 Cross slope
Cross slope of ramp runs shall not be steeper than 1:48. [2010 ADAS] Advisory 405.3 Cross Slope. Cross slope is the slope of the surface perpendicular to the direction of travel....
-
11B-405.3 Cross slope
Cross slope of ramp runs shall not be steeper than 1:48. Advisory 11B-405.3 Cross slope. Cross slope is the slope of the surface perpendicular to the direction of travel....
-
Boarding Pier Clearances: ADA Standard Section 1003.3.2
These requirements do not establish a minimum length for accessible boarding piers at boat launch ramps....
-
11B-1003.3.2 Boarding pier clearances
These requirements do not establish a minimum length for accessible boarding piers at boat launch ramps....
-
11B-1003.3.2 Boarding pier clearances
These requirements do not establish a minimum length for accessible boarding piers at boat launch ramps....
-
R407.3 Cross Slope
The cross slope of ramp runs shall be 2 percent maximum....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303. In transfer type shower compartments, thresholds ½ inch (13 mm) high...
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303. In transfer type shower compartments, thresholds 1/2 inch (13 mm) high...
-
608.7 Thresholds
608.7 Thresholds. Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303. In transfer type shower compartments, thresholds ½ inch...
-
§ 38.93(a)(2)
(2) If doorways connecting adjoining cars in a multi-car train are provided, and if such doorway is connected by an aisle with a minimum clear width of 30 inches to one or more spaces where...
-
c-i
If Yes, is a ramp or sloped hallway provided? Yes No If Yes, go to question E1-d....
-
f-viii
If the ramp or landing has a vertical drop-off on either side, is edge protection provided? [ADA Standards § 4.8.7] Yes No...
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface....
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
Shelves and Maneuvering Space
The space for a "T" turn requires at least 36 inches of width for each segment of the T and it must fit within a 60 inch by 60 inch area....