Search Results "Seat Width"
Commonly Searched Documents
- Kohler Veil™ One-Piece Elongated Dual-Flush Wall-Hung Toilet With Reveal® Quiet-Close™ Seat
-
11B-221.2.4 Temporary structures
Exception: When an entire seating section is placed on temporary platforms or other movable structures in an area where fixed seating is not provided, in order to increase seating for an...
-
11B-221.2.4 Temporary structures
Exception: When an entire seating section is placed on temporary platforms or other movable structures in an area where fixed seating is not provided, in order to increase seating for an...
-
11B-221.2.4 Temporary structures
Exception: When an entire seating section is placed on temporary platforms or other movable structures in an area where fixed seating is not provided, in order to increase seating for an...
- Bobrick B-3091 ClassicSeries® Recessed-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
- Bobrick B-3092 ClassicSeries® Recessed-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
-
M302.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface....
-
15(d)
HWI shall ensure that each Post-1993 Owned Hotel and Post-1993 Joint Venture Hotel has one removable tub seat for each and every accessible tub room in the hotel that does not already have...
-
608.5.2 Standard Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches (685 mm) maximum from...
-
4.1.2(5)(b)
(b) One in every eight accessible spaces, but not less than one, shall be served by an access aisle 96 in (2440 mm) wide minimum and shall be designated “van accessible” as required...
- Caroma® USA Invisi Series II Walvit Wall Hung Elongated Water Closet
-
11B-608.5.2 Standard roll-in type shower compartments
the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
11B-608.5.2 Standard roll-in type shower compartments
the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
M303.2 Wheelchair Spaces
A wheelchair space can be used to accommodate patients who use wheelchairs as well as other mobility devices and seating....
-
M302.1 General (Section-by-Section Analysis)
The MDE NPRM proposed that all diagnostic equipment used by patients in a seated position must comply with the technical requirements of proposed section M302....
-
608.5.2 Standard Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches (685 mm) maximum from...
-
§ 36.302(f)(4)
(4) Purchasing multiple tickets.
-
M303.2.1 Orientation
Wheelchair spaces shall be designed so that a patient seated in a wheelchair orients in the same direction that a patient not seated in a wheelchair orients when the diagnostic equipment...
-
M303.2.1 Orientation
Wheelchair spaces shall be designed so that a patient seated in a wheelchair orients in the same direction that a patient not seated in a wheelchair orients when the diagnostic equipment...
-
11B-608.5.2 Standard roll-in type shower compartments
) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
608.5.2 Standard Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches (685 mm) maximum from...
-
§ 36.302(f)(6) Ticket transfer
Individuals with disabilities who hold tickets for accessible seating shall be permitted to transfer tickets to third parties under the same terms and conditions and to the same extent as...
- Whitehall Mfg. WH2105BAR Bariatric Toilet Siphon Jet Type Off-Floor
-
11B-233.3.1.2.6.5 Additional requirements.
Interior door opening width complying with Section 11B-404.3.1. 3. Door and gate hardware complying with Section 11B-404.2.7. 4....