Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall is required to be 10 inches maximum....
Search Results "Platform Edge"
Commonly Searched Documents
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
-
T403.2 Boarding Direction
Lift platforms shall be designed to permit passengers who use wheelchairs the option to board the platforms facing either toward or away from the non-rail vehicle....
-
Transit Stops (R308.1) (Section-by-Section Analysis)
Boarding platforms at transit stops must be positioned to coordinate with vehicles to minimize the vertical and horizontal gaps....
-
11B-406.5.10 Diagonal curb ramps
Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow....
-
11B-406.5.10 Diagonal curb ramps
Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow....
-
R408.5 Nosings
The radius of curvature at the leading edge of the tread shall be 13 mm (0.5 inch) maximum....
-
Post-Mounted Objects [§307.3]
Post-Mounted Objects [§307.3] Free-standing objects with leading edges 27” to 80” high that are mounted on posts or pylons cannot protrude more than 12” into circulation paths....
-
Thresholds [§404.2.5]
The edge must be beveled 1:2 maximum above a height of 1/4”....
-
Adjustable gap protocol
Adjustable gap protocol: From initial setup, just the horizontal distance between the WMD and platform was incrementally increased by placing plywood blocks of 3.5” (8.9cm) width between...
-
Components (M303.4)
In addition to providing knee and toe clearance at the breast platform (see M303.2.4), the height of the breast platform was identified as critical to ensuring that mammography equipment...
-
DEFINITIONS
“Content Provider” means any non-edX organization or institution that creates and/or provides content on www.edx.org, the Platform, or edX’s mobile applications....
-
4.4.1 Overview of Mammography Accessibility Considerations
Recognizing that the movable breast platform is the main action point, recommendations define each component in relationship to the breast platform....
-
Seat Width Evaluation
The 5th percentile wheelchair users however required transfer platform width of 25 inches if there were grab bars on the platform and 27 inches without the grabs bars. ...
-
504.5 Nosings
The radius of curvature at the leading edge of the tread shall be ½ inch (13 mm) maximum....
-
504.5 Nosings
The radius of curvature at the leading edge of the tread shall be 1/2 inch (13 mm) maximum....
-
Spout Location [4.15.3]
It is important that the spout be located at the front edge. The trajectory of water flow must be vertically "parallel" or "nearly parallel" to the face of the unit....
-
§ 38.125(b)(2)(i) Requirements
The lift shall deploy to all platform levels normally encountered in the operating environment....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
504.5 Nosings
The radius of curvature at the leading edge of the tread shall be ½ inch (13 mm) maximum....
-
Handrail Clearance and Cross Section [§505.5, §505.7]
Handrails can have circular or non-circular cross-sections, but must have rounded edges. The gripping surface and adjacent surfaces must be free of abrasive or sharp elements....
-
12162(a)(4)(A)(i)(II)
(II) such passenger can exit to the platform from the car such passenger occupies, move down the platform, and enter the adjacent accessible car described in subclause (I) without the necessity...
-
Measuring Door Openings
Measure the clear door opening from the edge of the doorstop to the edge of the door (not to the door jamb)....
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
M302.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...