The 1991 Standards do not allow an in-swinging door in a toilet or bathing room to overlap the required clear floor space at any accessible fixture....
Search Results "Input Floor"
Commonly Searched Documents
-
Alterations and Water Closet Clearances in Single-User Toilet Rooms With In-Swinging Doors (Section-by-Section Analysis)
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
- American Standard Acrylic Shroud for American Standard Selectronic Faucets
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
Based on input received from a panel of experts jointly convened by HDR and the Department to discuss benefits-related estimates and assumptions used in the RIA model, it was assumed that...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. # 28)
Based on input received from a panel of experts jointly convened by HDR and the Department to discuss benefits related estimates and assumptions used in the RIA model, it was assumed that...
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
.); and adequate clear floor space inside the room for side transfers and use of lift equipment....
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
Plan 6B: 12-Foot Wide Accessible Guest Room
• Recessed lavatory with vanity counter top permits shorter rear grab bar at water closet (section 604.5.2); • Circular turning space in room (section 603.2.1); • Required clear floor...
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
For example, the tile or other floor finish must extend under the removable base cabinet....
-
A4.5.1 General
It is recognized that the coefficient of friction varies considerably due to the presence of contaminants, water, floor finishes, and other factors not under the control of the designer...
-
Plan 4B: 13-Foot Wide Accessible Guest Room
• Recessed alternate roll-in shower location permits shorter rear grab bar at water closet (section 604.5.2); • Circular turning space in room (section 603.2.1); • Required clear floor...
-
Plan 6A: 12-Foot Wide Accessible Guest Room
• Recessed lavatory with vanity counter top permits shorter rear grab bar at water closet (section 604.5.2); • T-shaped turning space in room (section 603.2.1); • Required clear floor...
- Bobrick Accessibility Video -- Design for Turning Radiuses
-
26.1 Q. Is a parallel approach required at the shower, as shown in Figure 7(d) of the Guidelines?
A. Yes. For a 36 x 36 shower, as shown in Figure 7(d), a person in a wheelchair would typically add a wall hung seat. Thus the parallel approach as shown in Figure 7(d) is essential...
-
3.4.5 Grade
The clear ground space and turning space required by section 3.4.3 shall have a slope of no more than 1:48 (2 percent) in any direction. Exception. When the surface is not paved...
- Access Board: Accessible Route Openings
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...